Laserfiche WebLink
Lyle Oman <br /> From: Kate Jerke (kate@allstartoday.com] <br /> Sent: Thursday, January 19, 2012 8:06 AM <br /> To: Lyle Oman <br /> Subject: RE: 4050 bayside <br /> Hi Lyle, <br /> Please see responses below... <br /> Stud size :The suds will be 2x6 <br /> Window and door header size: ( front ) 2-11 7/8" LVL 9-9 3/8" with 4%" bearing on each side, ( dbl wide enrty door) 2- <br /> 2x10 78" with 3" bearing on each side, ( side window ) 2-2x10 7-5 7/8" with 3" bearing on each side. <br /> Wall floor and roof sheathing type and size: %2" OSB for wall and roof sheathing, 3/4 "t&g cdx for floor sheathing <br /> Rafter size and spacing: 2x8 rafters 16" OC <br /> Wall, floor and roof insulation type and R-values: Floor will be insulated to R38, walls to a R19, and roof to be foamed <br /> with closed cell foam <br /> Siding, roofing and below joist sheathing type: Walls and below joist to be sheathed with 5/8" t-1114x8 sheets with 1x4 <br /> cedar trim, roof to be 16" medium hand split blue lable. <br /> Heat source: Forced airc <br /> Please let me know if you have any other questions. Thank you! <br /> KateJerke <br /> 763-479-8700 <br /> Allstar Construction <br /> Residential Division <br /> � <br /> Fax: 1-763-479-6600 <br /> www.Al IstarTodav.com <br /> From: Lyle Oman [mailto:LOmanCa�ci.orono.mn.usl <br /> Sent: Wednesday, January 18, 2012 3:53 PM <br /> 1 <br />