My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-00733 (New structure)
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
3382 Bayside Road - 05-117-23-14-0069
>
Permits/Inspections
>
2010-00733 (New structure)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:19:03 PM
Creation date
1/15/2016 1:27:34 PM
Metadata
Fields
Template:
x Address Old
House Number
3382
Street Name
Bayside
Street Type
Road
Address
3382 Bayside Rd
Document Type
Permits/Inspections
PIN
0511723140069
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Job Site Address: 3 3 SZ $a�CSrD E T�aa� � ����O��D <br /> �, <br /> "�ATEGORY 1" ALTERNATE FOR ��°Jj � � Z;'° <br /> ONE & TWO FAMILY DWELLINGS ClTY 0�o�oNo <br /> INSTRUCTIONS: This alternative may be used for one-and two-family dweliings built to meet the Category 1 requirements of <br /> Minnesota Rules,Chapter 7670. Complete Parts A,B,and C. Clearly mark plans with: insulation R-values; window and skylight U- <br /> values; size and type of equipment; equipment controls; and location of vapor retarder and windwash barriers. More detailed <br /> information can be found in the Minnesota Energy Code summary sheets available from the Minnesota Department of Commerce. <br /> Part A. BUILDING ENVELOPE <br /> ---_ __ ._-. -__ --=. :._ _ -, <br /> : _ _z. _ ____ =-_- <br /> Check proposed envelopejoint sealing option � ❑ Prescriptive(caulking,gaskets,etc.) ❑ Performance(test per 7670.0470 subp.7.C.) <br /> _ _ <br /> Check thermal energy calculation option used-� , ❑ "Cookbook" (complete worksheet below) � MnCheck method(attach report) <br /> ❑ Performance (attach U-value calculations) ❑ Systems Analysis method(attach analysis) <br /> "Cookbook" Worksheet M�M�M�Q��NTS <br /> (for"Cookbook"o rion only) <br /> ❑ Ceiling Insulation: Minimum R-38 with 7%"energy heel; or <br /> IrrsTxucT�otvs Minimum R-44 with low truss heel; or <br /> Step 1. Check item(s)that design meets on Minimum Requirements list Minimum R-38 with R-5 sheathin when no attic. <br /> to the right.Must meet all items to use"Cookbook"option. ❑ En Doors: Max.U-value of 030 or 1'/4"solid wood with storm <br /> Step 2. Indicate proposed wa11 type on table below. ❑ Rim Joist Insulation: Minimum R-19 <br /> Step 3. Indicate Window U-value and source. ❑ Floors over unconditioned s aces: Minimum R-24 <br /> Step 4. Verify total window(including area of all foundation windows) ❑ Foundation Insulation: Minimum R-10 <br /> and door area is equal or less than allowable percentage. ❑ Foundation windows: %z"insulated lass,wood or vin 1 frame <br /> Ti ABLE FOR DETERMINING MAXIMiJM WINDOW AND DOOR AREA <br /> Maacimum Allowable Total Window and Door Area as : <br /> a Percentage of Exposed Wall 12% 14% 16% 18% 20% 22% 24% 26% 28% <br /> Wall T e Standard Framin )' Ma�mum Average Window U-value(exce t foundation windows): <br /> ❑ 2x4,R-13 insulation, R-7 sheathing 0.55 0.47 0.41 0:36 033 0.30 0.27 0.25 0.23 ' <br /> ❑ 2x4,R-15 insulation, R-5 sheathing 0.52 0.45 0.39 035' 0.31 0.28 0.26 0.24 0.22 ' <br /> ❑ 2x6,R-19 insulation,<R-5 sheathin 0.48 0.41 0.36 032 0.29 0.26 0.24 0.22 0:21 ` <br /> ❑ 2x6,R-19 insulation, R-5 sheathing 0.56 0.48 0.42 037 0.34 031 0.28 0.26 0.24 <br /> ❑ 2x6,R-21 insulation,<R-5 sheathin 0.51 0.43 0.38 034 030 0.28 0:25 0.23 0.22 <br /> ❑ 2x6,R-21 insulation, R-5 sheatlling 0.58 0.50 0.44 039 0.35 0.32 0.29 0.27 0.25 <br /> Wall T e (Advanced Framin ): Maacimum Avera e Window U-value(exce t foundation windows`. <br /> ❑ 2x6,R-19 insulation,<R-5 sheathing 0.52 0.45 0.39 035 031 0.28 0.26 0.24 0.22 ' <br /> ❑ 2x6,R-19 insulation, R-5 sheathing 0.58 0.50 0.44 039 035 032 029 0.27 0.25 <br /> ❑ 2x6,R-21 insulation,<R-5 sheathin 0.55 0:47 0.41 036 033 030 0.27 0.25 0.23 <br /> ❑ 2x6,R-21 insulation, R-5 sheathing 0.60 0.52 0.46 0.41 0.36 033 0.30 0.28 0.26 <br /> Window U-value: � Source: ❑NFRC ❑ ASHRAE 1993 Handbook� <br /> 100 X � - - ° < �-_�o._ <br /> window&door area gross exposed wall area DESIGN ALLOWABLE (from table above) <br /> MINNESOTA ENERGY CODE - WHICH RULES MAY I USE ? <br /> TYPE OF RESIDENTIAL BUILDING APPLICABLE RULES ' <br /> Detached R-3 occupancy 1-and 2-family dwellings Chapter 7672; or <br /> �xamples: single family,twin homes,duplexes Chapter 7670"Category 1",with statutory depressurizarion a�d ventilation requirements <br /> Attached R-3 occupancy dwellings Chapter 7674; or <br /> Exam les: tri lex townhouses and row houses Cha ter 7670 with either"Category 1" or "Category 2": rovisions <br /> R-1 occupancybuildings of 3 stories or less Chapter 7674; or <br /> Exam les: condominiums or apartinents _Chapter 7670 with either"Category 1" or "Category 2". provisions <br /> R-1 occupancy buildings over 3 stories high Chaptet 7676 <br /> Exam les: high rise condos or a artments �s�� � <br />
The URL can be used to link to this page
Your browser does not support the video tag.