Laserfiche WebLink
� Rhvac-Residential8�Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing 8�Heating XXXX Bayside Traii Orono BAYSIDE MODEL <br /> PI mouth MN 55447 Pa e 4 <br /> Tota! Buildin Summa Loads <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 596.3 16,084 0 16,923 16,923 <br /> SHGC, Window and Patio Door, u-value 0.31, SHGC <br /> 029 <br /> 11J: Door-Metal- Fiberglass Core 61.8 3,225 0 1,001 1,001 <br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 1129.5 4,484 0 127 127 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 15A-10sffc-4: Wall-Basement, concrete block wail, R-10 432 1,879 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 4'floor depth <br /> R20 12F-Osw: Wall-Frame, Custom, R-20 Insulation in 1912.8 10,984 0 2,059 2,059 <br /> 2x6 Cavity, no board insulation, siding finish,wood <br /> studs <br /> RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 359 1,562 0 494 494 <br /> Closed Cell Spray Foam <br /> R49 166-49: Roof/Ceiling-Under Attic with Insulation on 1986.9 3,976 0 2,331 2,331 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R-49 Blown Insulation, No <br /> Radiant Barrier, Vented Attic,Asphalt Shingles <br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1867 4,386 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 26 80 0 10 10 <br /> R-3__0_blanket_insul_ation, any cove.r__ <br /> __ _ _ __ __. _ _.__ ._ _ _._. _. _ _ <br /> Subtotals for structure: 46,660 0 22,945 22,945 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 722 3,783 4,505 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 0, Summer CFM:0 0 0 0 0 <br /> Ventilation: Winter CFM: 155, Summer CFM: 155 5,757 4,259 1,059 5,318 <br /> Humidification (Winter) 13.42 gal/day : 4,920 0 0 0 <br /> AED Excursion: 0 0 3,710 3,710 <br /> Total Building Load Totals: 57,337 6,181 32,876 39,058 <br /> Check Fi ures <br /> Total Building Supply CFM: 1,491 CFM Per Square ft.: 0.387 <br /> Square ft. of Room Area: 3,854 Square ft. Per Ton: 1,184 <br /> Volume(ft') of Cond. Space: 34,685 <br /> Buildin Loads <br /> Total Heating Required Including Ventilation Air: 57,337 Btuh 57.337 MBH <br /> Total Sensible Gain: 32,876 Btuh 84 % <br /> Total Latent Gain: 6,181 Btuh 16 % <br /> Total Cooling Required Including Ventilation Air: 39,058 Btuh 3.25 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:\...�XXXX Bayside Trail Orono BAYSIDE MODEL.rh9 Monday, April 20,2015, 12:58 PM <br />