My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00763 - septic mound system
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Trail
>
200 Bayside Trail - 06-117-23-22-0027
>
Septic
>
2015-00763 - septic mound system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:09 PM
Creation date
1/15/2016 12:47:40 PM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Bayside
Street Type
Trail
Address
200 Bayside Tr
Document Type
Septic
PIN
0611723220027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Basic Pump Selection Design <br /> Urv�veus�TY <br /> MinnesotaPollution Worksheet OF MINNESOTA �" <br /> �o�trol A enc �'�-�� <br /> 1. PUMP CAPAGTY Project ID: 5!19;15 v t 1.09.22 <br /> Pumping to Gravity or Pressure Distribution: � �ra��t, Ci,r vreswre Selection required 2 <br /> 1. If pumpmg to gravity enter the gallon per m�nute of the pump: �GPM i f0�45 gpml <br /> 2. If pumping to a pressunzed distnbution sys[em: 36.0 GPM <br /> �Line 11 0l P�essure Oistributionl "•+�^'•^'�+^' <br /> a�w��a oi e,una« <br /> 2. HEAD REQUIREMENTS <br /> ��r <br /> A. Elevadon Difference 23 ft '""',Y�� - <br /> between pump and point of discharge: �"�°�°�. m �`„„01�' <br /> B. Dis[nbution Nead Loss: �ft � ' <br /> � <br /> C. Additional Head Loss: �ft Idue to spedal equipment.etc.i <br /> Table I.Friction Loss in Plastic Pipe per 100ft <br /> Distribution Head Loss Pi Diameter linchesl <br /> Gravity Distribution = Oft Flo�v Rate Pe <br /> IGPMI t 1.25 1.5 2 <br /> Pressure Distribution based on Minimum Average Head 10 9.7 3.1 1.3 0.3 <br /> Value on Preswre Distribution Worksheet: �2 12,$ 4.3 1.8 0.4 <br /> Minimum Avera e H�d Distribution HQad Loss �4 �7,p 5,7 2.4 0.6 <br /> 1ft 5ft �6 2�,g ' 7.3 I 3.0 0.7 <br /> 2ft 6ft 18 9.1 3.8 0.9 <br /> Sft 10ft Zp ' 11.1 ' 4.6 1.1 <br /> 25 16.8 6.9 1 J <br /> D. 1.Supply Pipe D�ameter. 2.0 1n 30 23.5 9.7 2.4 <br /> 35 12.9 3.2 <br /> 2.Supply Pipe Length: 90 ft 4Q � , 16.5 4.t <br /> E. Friction Loss in Plastic Pipe per t00ft from Table I: 45 i ' 20.5 5.0 <br /> 50 � I 6.1 <br /> Fnction Loss = 3.32 ft per 100ft ot pipe 55 ' I 7.3 <br /> 60 8.6 <br /> p, Determine Equivalent Pipe Length from pump discharge to soil dupersal area discharge 65 10.0 <br /> point. Estimate by adding 25�to suppty pipe length for fitting loss. Supply Prpe Length �p 11.4 <br /> (D.2) X 1.25=Equivalen[Pipe Length 75 13.0 <br /> 90 ft X 1.25 = 112.5 ft 85 16.4 <br /> 95 20.1 <br /> G. Calculate Supply Friction Loss by mutt�ptying Friction Loss Per t00ft Iline E�by the Equivalenf Pipe length ILine F)and divide by 100. <br /> Suppty FncUon Loss= <br /> 3.32 fc Pe��oofc x 112.5 rc � ioo = 3.7 rc <br /> H• Total Head requirement u the sum of[he Elevotion DifJerence Il�ne A1, the Dutnbution Head Loss ILine B1,Additional Head Loss iLine C),and the <br /> Supply Friction Loss ILine G i <br /> 23.0 ft - 5.0 fc - r- tc - 3.7 rc = 31.7 ft <br /> 3. PUMP SELECTION <br /> A pump must be selected to det,ver at least 36 GPM ILine t or Line 2)with at least 32 feet of total head. <br /> Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.