�. 200 Bayside Trail, Orono, Minnesota <br /> � July 3, 2015 <br /> Page 2 of 2 <br /> published by NCMA in 2009. If soil conditions, proposed wall layouts, or other design parameters vary <br /> from that assumed, a revised analysis may be needed. Please call me if you have any questions or need <br /> more information. Thank you. <br /> Sincerely, <br /> � �� � _ <br /> � <br /> Paul Schimnowski, PE <br /> MN#40126 <br /> DESIGN PARAMETERS AND PROVISIONS <br /> 1. REFER TO BOULDER RETAINING WALL INDUSTRY STANDARD SPECIFICATIONS. <br /> 2. SEE PRODUCT MANUFACTURER INSTALLATION RECOMMENDATIONS FOR CONSTRUCTION <br /> SEG�UENCE AND INSTALLATION NOTES. <br /> 3. NO PRODUCT/MATERIAL SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN <br /> PERMISSION OF CRITERIUM-SCHIMNOWSKI ENGINEERS. <br /> 4. OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR ENSURING THE <br /> CONDITIONS STATED HEREIN ARE ACCURATE PRIOR TO AND DURING CONSTRUCTION. <br /> NOTIFY CRITERIUM IN WRITING OF ANY DISCREPANCIES OR CHANGES TO THE CONDITIONS <br /> SHOWN ON THESE DOCUMENTS. <br /> 5. REFER TO WALL ELEVATION NOTES FOR WALL SURCHARGE LOADINGS AND SLOPES AT <br /> TOP AND BOTTOM OF WALL(S). REFER TO WALL CALCULATIONS FOR BEARING CAPACITY <br /> REQUIREMENTS. <br /> 6. FINAL SITE GRADES AND ROOF DRAINS SHALL DIRECT RUNOFF AWAY FROM ANY <br /> RETAINING WALLS. <br /> 7. CRITERIUM ASSUMES NO LIABILITY FOR INTERPRETATION OF SUBSURFACE CONDITIONS, <br /> SUITABILITY OF SOIL DESIGN PARAMETERS AND INTERPRETATIONS OF SUBSURFACE <br /> GROUNDWATER CONDITIONS. <br /> 8. THE OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR CONTACTING THE <br /> WALL DESIGN ENGINEER TO SCHEDULE A SITE VISIT PRIOR TO THE START OF BLOCK <br /> PLACEMENT. <br /> 9. THE WALL DESIGN WAS PERFORMED USING DESIGN GUIDELINES PRESENTED IN THE <br /> SECOND EDITION OF THE "DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS" (DMSRW). <br /> PUBLISHED BY NCMA IN 1996. <br /> 10. THE DESIGN OF THIS RETAINING WALL WAS BASED UPON INFORMATION NOTED ON THE <br /> KEY PLAN. <br /> 11. THE INFORMATION PROVIDED WITHIN THESE DOCUMENTS IS FOR THE STRUCTURAL <br /> DESIGN OF THE PROPOSED WALL(S) ONLY. THE REQUIREMENTS FOR AND/OR WORK <br /> RELATED TO HANDRAILS, GUARDRAILS, OR OTHER LIFE/SAFETY ISSUES ARE EXCLUDED <br /> FROM THESE DOCUMENTS AND ARE TO BE PROVIDED BY OTHERS. <br /> 12. RESPONSIBILITY FOR GLOBAUSLOPE STABILITY RESTS WITH THE SITE CIVIL OR <br /> GEOTECHNICAL ENGINEER. <br /> CRITERIUM-SCHIMNOWSKI ENGINEERS <br /> TEL 651 779-7700 <br />