Laserfiche WebLink
� <br /> 4' <br /> Joseph Olson D.B.A. <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J.Olson--NIICA License#810 <br /> 11481 R,iverview Rd.NE,Hanover,MN 55341 <br /> (763)49&8779 Faz(763)498-8290 <br /> John&caroi susacker ���Np COpy <br /> 2380 Abingdon Way <br /> Orono,Hennepin County <br /> This oirsite Sewage Treatme�System is designed for a Type III,five bedraom home in accordance with <br /> the Minnesota Pollution Co�col Agency Chapter 7080 and local ordinances. <br /> The seasonally saturated soils were located at 18-26 Inches(Mottled soil).Due to the existing system an <br /> OTHER pressurized Mound System will need to be installed to treat septic ei�luent The bottom of the <br /> treatment area must be located at least 3'above the saturated soils.Other systems need to be monitored. <br /> The monitoring plan is to he set by the LUG.The home owner is responsible for the monitoring plan. <br /> The lines hetween the drop bmces should be broken up so e$luent can no longer flow between the trenches. <br /> The existing trenches are not overloaded. <br /> A water meter must be insblled'm the house. <br /> The soils at a depth of 12"have a percolation rate averaging 6 MPI. ��ON�C�l'Y <br /> � All neighboring wells are located greater than 100'away from proposed trea�nent area. <br /> A 130(}gallon pumping chamber will need to be installed to lift the effluent to the treatment area.The <br /> power supply and switches must be loc�ted outside the manhole and pumping chamber in a weatherproof <br /> enclosure.A waming device must be installed with light and sound devices;t�is is in case of a pump <br /> failure. <br /> The manifold and supply line must have back drainage to the pumping chamber.The distribution pipes <br /> shall have their ends capped.Be s�e the rock and sand fill materials are clean.The sod layer below the <br /> entire mounded azea must be tumed over,just break up the sod and be s�e not to over work. <br /> Keep all heaw eauioment off of t6e orouosed treatment areas before durin¢and after constraction. <br /> With proper installation and maintenance,this system should have no pmblem in treating septic effluent <br /> effectively. <br /> Nothing other than gray water,(laundry,showers,etc.)Human water and toilet tissue should be disposed of <br /> into the septic tanks.Garbage disposals are not recommended.Additives must not be used;they may cause <br /> harmful damage to your septic system.It is recommended that you pump the tank every year for 1 tank <br /> every two years for two tanks. <br /> sm��ly, �1'�'Y�F ORONt) <br /> � �e�c ,rR� � , t a�rt <br /> O1�ON0 COP�C �P�� � <br /> -'``��� '��—PERMI't'Nfl�. <br /> �-'� Joseph J.Oison DATE <br /> AS�PHOY�D AS 8UdM1't1�11 <br /> � APPkOVEQ VYITH CORRECIROI�SS A9 NA7`�D <br /> AiOT APPRQVED-CORRBCT&RE9UBMIT <br /> �a1 �a� t�p 7'hcsc commcats are for your informatian. AU r�rar&sficll bb dsat <br /> ��7�a7r�e�fei���rvR tn Pall eampliance aith all appUcahle septic aad zoning codo. <br /> +���� ������u��� Requiccments iacluding itema nat speciCcallq noted 1n tbia tevle� <br /> ""�'�p"�pryn�@,�►tsf, �@�tep��'p� KEEt'THIS PLAN SET ON 51T�AT AL[.TIMES <br /> �ii�r1/�l3f�ii p1i�i1Q���ai'iN�l i�WW�e <br />