r . <br /> ; . <br /> TO: Grreg Gappa,Public Services Director <br /> FROM: Chris Pence,On Site Systems Manager <br /> DATE: September 23, I999 <br /> SUBJECT: Septic Review for 480 Russell Ave. <br /> The existing septic system on 480 Russell Ave. is a nan-comp�iant septic system and needs to be <br /> repaired by 12/31/20U2. The septic sytem failed due to a lack of a state required ttu�ee foot <br /> separation between the ordinary lugh water table and the bottom of the draiafield. <br /> A site inspection was conducted to determine if there,$re any reasonable sites available for a <br /> septic system. There does not appear ta be any availabie sites for a standazd septic system. The <br /> maJ or reason is siope. The slope of the land is too high and is not conducive for a septic system. <br /> The slape is over 6%, which is the maximum slopc that city code will a11ow. <br /> Staff recommends allowing thi.s property to connect to the city sewer system.because there aze no <br /> sites due to excessive slope. If more definitive information is needed,the property owner will <br /> need to hize a state licezised site evaluator to test the soils at tlus site. <br />