Laserfiche WebLink
, <br /> FILE#15-3769 � <br /> October 15,2015 <br /> Page 4 of 6 <br /> an event when the creek had flooded the rear of the prior garage at an elevation around 932'. <br /> The new garage will be located with its floor at 933.5' and would not be expected to flood. <br /> Side Setback Variance <br /> The proposed side setback of 5 feet is much better located than the prior garage which was <br /> within a few inches of the lot line. Moving the garage to meet the 10' side setback would result <br /> in an unusable driveway entrance to the garage and require removal of portions of the existing <br /> deck. At 21 feet in width, the garage is about as narrow as possible while still remaining <br /> functional for storage of two vehicles. <br /> Average Lakeshore Setback Variance <br /> The Average Lakeshore Setback variance is necessary because each of the adjacent properties <br /> abut the 929.4' OHWL contour for Lake Minnetonka at the creek bank. The average setback line <br /> runs approximately east-west about 5 feet north of the north wall of the proposed garage, so <br /> the entire garage would be an encroachment. The property to the immediate east at 3407 <br /> Eastlake Street will have its lower views of Stubbs Bay encroached upon by the proposed <br /> garage. While the new garage will encroach lakeward approximately 8 feet less than the garage <br /> that was on the property until 2011, the new garage as designed will have a peak height of <br /> approximately 15.5 feet, while the old garage had an estimated peak height of 9.5 feet based on <br /> photos in City files.The impacts on the neighbor's views of the lake could potentially be reduced <br /> by one or more of the following design revisions: <br /> - Decrease proposed roof pitch from 6/12 to 4/12 or 3/12; a pitch flatter than <br /> 3/12 is not recommended, however; <br /> - Re-orient the peak from north-south to east-west; <br /> - Change to a hip roof rather than a gable roof; <br /> - Reduce the wall height of the garage. <br /> Analysis <br /> This property is severely limited by the size and shape of the lot, the location and orientation of <br /> the existing house, and the limitations imposed by a creek that is considered as lakeshore for <br /> zoning purposes. In staff's opinion the proposed garage location would appear to be reasonable <br /> for a minimum-sized detached 2-stall garage. Attaching a garage to the east side of the house <br /> could eliminate the average setback variance but would likely require significant remodeling of <br /> the house, could probably only be 1 or 1-1/2 stalls, and still would likely require a side setback <br /> variance. Moving the proposed garage forward and closer to the house would require a <br /> variance to the requirement for a 10' separation between structures. There is simply not <br /> enough room to place a garage any closer to the street than the existing house. <br /> The fact that a 2-stall garage existed on the site for many decades suggests that replacement <br /> with a new garage at a location that is not as non-conforming as that of the old garage may be <br /> reasonable and justified. The applicants have worked with staff and their surveyor to minimize <br /> the extent of the side setback variance and to reduce hardcover. The structural coverage <br /> variance is minimal and a reduction of 16 sf may be feasible but perhaps unwarranted. <br /> Staff would recommend that the garage design be modified to reduce the magnitude of the <br /> view encroachment if possible. This is a discussion Planning Commission should have with the <br /> applicants. <br />