My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-15-2015 Planning Commission Packet
Orono
>
Planning Commission
>
2015
>
06-15-2015 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2016 11:49:25 AM
Creation date
1/12/2016 11:47:11 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
612
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
. �� � <br /> 15-3739 <br /> May 1 B,2015 <br /> Page 4 of 9 <br /> Gene�ral Site Characteristics <br /> The property abuts Mooney Lake, a Recreat�onal Deveiopment lake. A contiguous portion of an <br /> over 40 acre native Maple-basswood forest exists in the northem portion of the property; the <br /> southern portion of the praperty consists of established prairie with scattered wetlands. The plan <br /> reflects delineated wetland in 10 distinct basins with two additional created ponds neax iVlooney <br /> Lake. The eastern portion of the property also contains areas of steep slopes or bluffs. Lot 2 <br /> Block 1 has slopes of approximately 20% at its steepest, while the slopes at the site of the <br /> existing residence on Lot 6 Block 1 exceed 30% and would be considered as bluffs. <br /> Lot Layout and Lot Standards <br /> Proposed Lots 1 and 2, Block 1 will be accessed off of Sixth Avenue North via a private road <br /> contained within a 50-foot out�ot; likewise a 50-foot private road outlot with cul-de-sac will <br /> provide access to Lots 3 through 7, Block 1 and Lots 1 and 2, block 2. Lots 1 and 2, Block 3 will <br /> have individual driveway access directly off of Hunter Drive. All lots are proposed to be served <br /> with private wells and septic systems. Septic testing has been conducted and the test reports <br /> have been reviewed by the City's consulting ISTS inspector- see Exhibit F. <br /> Mooney Lake has a 100-foot structural setback requirement from the lake for lots served by <br /> private septic systems. Average lakeshore setback restrictions will apply to each of the lakeshore <br /> iots. According to the RR-1 B Zoning District standazds all of the lots must contain 2.0 dry, <br /> buildable acres and meet a 200' width requirement at the road frontage as well as at the 50-foot <br /> principa.l bui�ldang setback from the road (or 100-foot lakeshore structural setback). Stormwater <br /> Quality Overlay District hardcover restrictions apply to the lakeshore lots (Hardcover Tier 1, <br /> 25% HC limit) as well as Lots 1 and 2, Block 2 (assigned to Hardcover Tier 2 - 30% HC limit - <br /> per the methodology of Code Section 78-1741) which are also wholly or partially within 100� <br /> feet of Mooney Lake. <br /> Following is a brief review of each proposed lot, with applicant's comments excerpted from the <br /> Conservation Design Report: <br /> Lot 1, Block 1: This Iot is shown as having 4.0 total acres of which 3.5 is shown t� be dry <br /> buildable azea Wetland Z is shown to be located entirely within this proposed lot. This lot <br /> is proposed as a lakeshore lot with 200 feet in width at the shoreline. The slope leading <br /> from the lake averages approximately 18%. It appears a house can be located on this <br /> property meeting the required 50' reaz, 100' lake, 30' side and 35' wetland setbacks. A <br /> portion of tius property is currently shown to be established prai.rie vegetation. <br /> Applicant's Con�ervation Design Report Comments:Prairie grass preservation shall be <br /> enjorced surrounding the wetland on the southerly boundary of the property.Access is oJ�' <br /> of Outlot E from County Road 6. <br /> Lot 2, Block I: This lot is praposed as a lakeshore lot with approxilnately 240 feet in width at <br /> the lake and will have 3.39 acres, of which 3.0 acres is upland. This lot is proposed to be <br /> served via a 30-foot driveway oufilot (Outlot G) off of the private road and therefore is <br /> defined as a "back lot". Back lots have additional dimensional requirement of 150% of the <br /> zoning district requirement or in this case 3.0 acres is the minimum required, aud setbacks <br /> must also meet 150°/a of the sta�ndard. There aze also azeas of steep slopes on this pro�erty, <br /> up to 20% at the steepest. It would be appropriate to show rthe required setbacks on the <br /> prel'uninary plat drawings to show where a house might be developed on this Lot. <br />
The URL can be used to link to this page
Your browser does not support the video tag.