My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1987-11-16 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1300 French Creek Drive - 10-117-23-32-0015
>
Septic
>
1987-11-16 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2026 3:16:01 PM
Creation date
6/11/2026 3:08:31 PM
Metadata
Fields
Template:
x Address Old
House Number
1300
Street Name
French Creek
Street Type
Drive
Address
1300 French Creek Drive
PIN
1011723320015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br />i <br />S-P TESTING, INC. <br />961 KATYDID LANE <br />ST. MICHAEL. MN 66376 <br />467-3666 <br />mvEiHmMEiis <br />NOV I 91987 <br />j <br />November 16/ 1987 <br />John Laurent & Assoc. <br />Lot 7# Block 2, French Creek <br />OronOf Henn. Co.# NN« <br />This system is designed for a Type 1, five bedroom home and in accordance <br />with the Minnesota Pollution Control Agency standards WPC 40 and local <br />ordinances• <br />The soils on this site are typical of SCS soils mapped - AnB - Anoka loamy <br />fine sand. The lot boundries have been changed since the original plot. <br />The north property line has been moved to include test holes from <br />lot 6, Block 2. A seasonally high water table was not present in these <br />borings. Percolation rates were .9 min/inch for TH#1 & 1.8 min/inch for <br />THi6. A standard treatment system may be installed. <br />A pumping chandaer w;ill need to be installed to lift the effluent to the <br />treatment area. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must be <br />installed with a light and sound device# this is in case of a pump failure. <br />(Mercury floats are. a good method). The supply line pipe must have back <br />drainage to the pumping chamber. <br />All neighboring- wells are located more than 100* away from the proposed <br />treatment area. <br />Keep all heavy equipment off of the proposed treatment area before and <br />after construction as much as possible. The treatment area should be <br />marked off before construction. <br />With proper installation and maintenance# this system should have no <br />problem in treating septic effluent effectively. <br />It is recommended that the septic tanks be pumped every 2 years <br />t <br />I <br />— <br />Steven B. Schirmers <br />SBS/ds <br />Setfeedf^r—iertee T€U§ <br />Si^ SjrsMi IMr* <br />BBwSBSSSSiSBBiiP
The URL can be used to link to this page
Your browser does not support the video tag.