My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1988-07-08 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2740 Fox Street - 04-117-23-42-0005
>
Septic
>
1988-07-08 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2026 2:57:14 PM
Creation date
5/28/2026 2:55:13 PM
Metadata
Fields
Template:
x Address Old
House Number
2740
Street Name
Fox
Street Type
Street
Address
2740 Fox Street
PIN
0411723420005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />On N.re ,North, ,Sbort, of <br />Lake Minneronka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />OWNER V1'yl IIC bi S Sc_. I ADDRESS sr`�\ 74o rnx Sfree f %7t <br />PERMIT NO.'S. <br />DATES <br />CONTRACTORS <br />City Ordinance No. 210 requires that each on -site so, -pe treatment system in Orono be inspected on a regular basis. The on -site sewege <br />treatment system at the above address has been inspected and appears to fall into the t atagOry checked below. <br />(This is ❑ an existing system ❑ new construction) <br />1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears 'a be operating <br />properly. <br />02 Does not meet all current City standards for new construction 11978 Code$ but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />4 System may or may not meet current City standards for design, construction or location, but is failing to property treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or goundwalers, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Pleas contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION.( m Checked items may require your action) <br />Tank ii. tion indicates: <br />Pumpout not nnaeded at this time. <br />StMide accumulation in tanks indicates they should be pump• <br />ed out this yew to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out ae soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface dificharge. <br />❑ Inspection risen misaing—tanks could not be inspected. <br />Ir epic ion risers 14" dia. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />❑ Inspection pipe is located directly over tank baffle. (Does not <br />give accurate messurement of solids accwnulation.l If tanks <br />haw not been pumped out within the last three years, they <br />shou!d be pumped out now. <br />Drainfield inspection indicates: <br />rainfield is dry, no surfacing evident. <br />Some evidence of surfecing, not critical yet. <br />❑ Orainfield is seturoted and visibly discharging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions to drainfield. Contact the City Inspector <br />immediatsty. Repairs must be completed within 90 days. <br />❑ Oramfield extent and condition unknown. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors Potential for System Failure Site Capabilities for <br />❑ Slope (depends on soil types, water Future Expansion <br />LJ Soil table, and system condition) ❑ Adequate <br />❑ High water table ❑ Low OFair <br />❑ Lot siee sum (sl/SI?A ct[k, ) 'Q'Poor <br />w« ❑ Lake, etland, stream High J ❑ Inadequate <br />ralnnage ❑ System is causing visible <br />surface discharge. <br />COMMENTS. <br />r ST141 N- <br />Date of Inspection k System t« <br />NoteIn the event that this ✓✓✓inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function property, but is merely an op-nion of the adequicy <br />of the system under current conditions based on the availeble information. <br />This report must be kept on the premises with system location and pumping reconh. <br />WHITE COPY I Inspector's File GOLD COPY / Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.