My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993-05-03 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2675 Fox Street - 04-117-23-43-0003
>
Septic
>
1993-05-03 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2026 11:33:46 AM
Creation date
5/28/2026 11:27:05 AM
Metadata
Fields
Template:
x Address Old
House Number
2675
Street Name
Fox
Street Type
Street
Address
2675 Fox Street
PIN
0411723430003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2675 Fox Sheet <br />Orono <br />(2) <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must he turned over, just break up the sod, be sure <br />not to over work. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must <br />be installed with a light and sound device, this is in case of a pump <br />failure. Mercury floats are a good method. <br />The supply line will need to be installed around the east end of <br />excavated ditch within 5' of the property line. Due to the high <br />water table, the supply line will need to be installed shallow <br />and be insulated to prevent freezing. Only the manifold and a <br />small section of the supply line will have drain back. Recommend <br />to add 12" to 18" of fill to cover the pipe north of the excavated <br />ditch near the east property line. <br />The existing tanks are block type and will need to be abandoned, <br />pumped & filled with soil. <br />All neighboring wells are located grE-ater than 100' away from the <br />proposed treatment area. <br />Keep all heavy equipment off of the proposed treatment area before and <br />after construction. The treatment area should be marked off before <br />construction. This Design is not valid & the System will need to <br />be relocated if failure to protect the areas proposed for On -Site <br />Sewage Treatment occurs. <br />With proper installation and maintenance, this system should have no <br />problem in treating septic effluent effectively. <br />CONT'D <br />
The URL can be used to link to this page
Your browser does not support the video tag.