Laserfiche WebLink
I~ U I\ l lJ lJ AL ~ L WA'--' L 11{ LA I f\11 1'-1 I ~ \::, 1 LM \'\Uh. I,~ I l LL I <br />' I\ <br />B. <br />C <br />D <br />E <br />F. <br />FLOW <br />Eslimal!'d ")<f) -·-----L~----gpd <br />nwasured X -----gpd <br />ff/ /YJycJ'- <br />OIV) <br />SEPTIC TANK VOLUME <br />·--"';l-'-"e.~t~&Jo-=~----gallons <br />SOILS (Site evalu~tjon data) <br />Depth to restricting layer = ____ '1~----feet <br />Maxim~ depth of system C -3 ft feel <br />Texture~"I ~Percolation rate \'21'::20 MP! <br />SSF la:2_ sq fl/ gpd <br />TRENCH BOTTOM AREA <br />H. For trenches with 6 inches of rock below the pipe: <br />A x F = __ x __ = __ sq ft of bottom area <br />I. For trenches with 12 inches of rock below the pipe: <br />A x F x 0.8 = __ x __ x 0.8 = __ sq ft of bottom area <br />For trenches with 18 inches of rock below the pipe: <br />A x F x 0.66 = __ x __ x 0.66 = __ sq ft of bottom area <br />K. For trenches with 24 inches of rock below the pipe: <br />Ax F x 0.6 = x x 0.6 = sq ft of bottom area <br />BED BOTTOM AREA <br />L. For Gravity beds with 6 or 12 inches of rock below the pipe; <br />1:s x Ax F = 1.5 x --x --= --sq ft of bottom area <br />For Pressure beds with 6 or 12 inches of rock below the pipe; <br />Ax F = __ x __ = __ sq ft of bottom area <br />ROCK VOLUME IN CU Ff <br />M. <br />N. <br />0. <br />Rock depth below distribution pipe plus 0.5 foot times bottom area: <br />M =Rock depth+ 6 inches x Area (H,I,J,L,K) <br />,( __ . t 05_ ft) x __ = __ cu ft <br />ROCK VOLUME IN CU YDS <br />Volume in cu ft divided by 27 <br />M + 27 = cu yds _ + 27 = __ cu yds <br />ROCK WEIGHT <br />Cubic yards times 1.4 = tons <br />Nx 1.4 = tons X 1.4= <br />· DISTRIBUTION <br />tons <br />(Checl< one p.3:s_e_~ on slope) __ Bed ( < 6% slope) <br />Trenches_._., Drop boxes (any slope) __ Distribution box(< 3%) <br />··. :·. . SYSTEM LENGTH <br />P. Seled width ~ ft <br />Q. Divide bottom area by width: (H, I, J, or K) + P = lineal feet <br />~ = lineal feet <br />Gravelless Pipe <br />( 10" :A x F + 3)= Lineal Feet ( 8" :Ax F + 2)= Lineal Feet <br />Chamber (A x F + width of chamber) <br />7;t2_x bTI_ + .3._=~ineal feet <br />LAWN AREA <br />R. Select trench spacing, center to center= J_ feet <br />S Multiply trench spacing by lineal feet Rx Q == sg ft of lawn art'i1 <br />-:+--~ == 2/l-Usu, ft <br />LAYOUT (Use other side) <br />Select an appropriate scale; one sguar<' == ---,.-~ feet <br />2. Shov,1 pertinent property boundaries, right-of-way, cascmc·nh <br />1. Show location of house, garage, driveway, and all olh<'r <br />improvements, existing or proposed <br />·L Show location and layout of sewage treatment system. <br />5. Show location of water supply well. <br />6. Dimension all set backs and separation distances. <br />Lo-f 5 <br />Esiima1cd Sr~!!' Fl<~,·~~ <i~llnn~I"'' llay <rpdl <br />----------.-----·--------- <br />Numtwr <br />of Typr I '!)•pc II Typ<' 111 Typ<' I\' <br />llcdtooms <br />2 300 225 180 t-.()•,t <br />3 450 300 218 "' 4 600 375 256 th, <br />5 750 4.~0 294 \·;due_, <br />"' 6 900 525 3:12 lhl· <br />7 !050 600 .no Ulh<'1 <br />8 1200 675 40~ {nlmnn, <br />Number Minimum Minimum <br />Septic Tank Capacity with of Liquid Ga1baic- <br />Bedrooms Capacity Disr><.1sal <br />(gallons\ (gallons) <br />2 or less 750 1.125 <br />3 or4 1,000 1.500 <br />5 or6 1,500 2,250 <br />7 or 8 2,000 3.000 <br />over9 Sec fig. C-6 (X 1.5) <br />Soil Ch;i.ractt!ristics & R~uin.J An-a~ hu St•wAJ:,t' ln•almt'nt <br />Pt>rcolation Rate !-<:i•LU.-ln-1 ~lk1n, <br />Soil Texture f"<"lt->11,,.... ,..,,d_.,. <br />Minul~ per inch !"1d.>\ f'<n"lu"" (mpi) ·~· <br />Faster than 0.1• Coarse Sand ---------- <br />0.1 to5 Sand 0.83 1.20 <br />0.1 to5 Fine Sand .. 1.67 0.60 <br />6 to 15 ~dyLoam L27 0.79 <br />16 to 30 . Loam 1.67 0.60 <br />31 to 45 , .. Silt Loam· 2.00 0.50 <br />. , .46 to 60 . ;. Clatl..oam 2.,20 0.45 <br />Slower than 60 .. 1• . lay --(0.24) ... r,,·,r. <br />. , . • Soil too coarse for sewage treatment. <br />· · : Use systems for rapidly penniablt! soils. <br />-Soil having SO'Y. or more of (int! or ver)' fine sand . <br />. ''.°'',Soil wllh too hlgha percentage of day for <br />· installation of an lngmund standard system. <br />T <br />2 irr.:1.Cover t f"''