My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Project Packet
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
440 Brown Road South - 03-117-23-42-0012
>
Land Use
>
16-3872, VAR
>
Project Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2026 11:54:14 AM
Creation date
4/16/2026 11:53:36 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
b. When an existing code system is repaired or expanded, such ISTS shall remain a code <br />system. Compliant systems, when repaired, shall be upgraded to a code system status <br />whenever such classification is reasonably attainable. <br />(4) Construction procedures. <br />a. Protection of drainfie/d area. Proposed drainfield areas shall be identified and marked off <br />on the lot at the time of the site evaluation and prior to any construction or grading <br />occurring in the area. The drainfield area sha ll remain undisturbed until drainfield <br />construction is commenced. No vehicular traffic shall be allowed in the drainfield area <br />either before or after drainfield installation. <br />b. Favorable weather required. Ora infield area or trench construction must not proceed if the <br />area is wet or has had rain within 48 hours. Mound or trench construction shall not proceed <br />unless the so il moisture content is below the plastic limit. <br />c. Construction inspection required. The contractor issued a permit for ISTS construction shall <br />perform all work according to the design specifications approved by the city for each <br />particular ISTS. All subsurface work, including building sewer, sewage tanks, distribution <br />system and soi l treatment area shall be inspected by the city inspector prior to backfilling <br />or covering of any portion thereof. It shall be the responsibility of the contractor to notify <br />the city at least 24 hours prior to the time an inspection will be requ ired, and it shall be the <br />responsibility of the contractor to ensure that the inspection is accomplished and the <br />construction is approved prior to any backfilling, covering or continuation of the <br />construction. <br />(Code 1984, § 12.30(5); Ord. No. 100 2nd series,§ 4, 2-10-1992; Ord. No. 147 2nd series,§§ 11 -15, 5- <br />13-1996; Ord. No. 199 2nd series,§ 1(12.30(5)), 5-8-2000; Ord. No. 38 3rd series,§ 1, 9-24-2007) <br />Sec. 78-420. -Area, height, lot width and yard requ irements. <br />(a) Height. No structure or building in the RR-18 district shall exceed 2½ stories and sha ll not exceed 30 <br />feet in height except as provided in section 78-1366. <br />(b) Lots . The following minimum requirements shall be observed: <br />--, ---r Side <br />Side Yard Rear Lot Lot Front <br />Area Width Yard Yard <br />Adjacent <br />Yard <br />(feet) (feet) (feet) <br />to Street (feet) (acres) ' (feet) <br />I --i---- <br />-~ <br />2 200 50 30 50 <br />Sec. 78 -1434. -Area restrictions. <br />In all R districts, no accessory building shall exceed 1,000 square feet of footprint area; except that <br />accessory structures in excess of 1,000 square feet will be allowed under the following conditions: <br />(1) Not more than one oversized accessory structure (OAS) shall be permitted on any property. An <br />oversized accessory structure is defined as an accessory structure of footprint a rea in excess of <br />1,000 square feet, except that the following non roofed accessory structures which exceed 1,000 <br />Page4
The URL can be used to link to this page
Your browser does not support the video tag.