Laserfiche WebLink
SITE EVALUATION REPORT <br />For Kraus Anderson <br />Sewage Treatment System <br />GENERAL INFORMATION <br />This design is for a Type 1, 4 bedroom home and in accordance with the Minnesota Pollution <br />Control Agency Standards and local ordinances. <br />A seasonally high water table was evidenced at 24 inches of depth in Soil Boring 7. The slope <br />is about 3%. <br />The soils at a depth of 12 in Test Hole 8 has a percolation rate of 13 minutes per inch. All <br />neighboring wells are located more than 100' away from the proposed treatment area. <br />NOTES: <br />Keep all heavy equipment off the proposed treatment area before and after construction as much <br />as possible. The treatment area should be marked off before construction. <br />With proper installation and maintenance this system should have no problem in treating septic <br />effluent effectively. <br />It is recommended that the septic tanks be pumped every 2 years. <br />MOUND SYSTEM: <br />Flow: 4 bedroom = 150 gallon/day/bedroom 150 x 4 = 600 gallons per day. <br />600 GPD x .83 = 500 square feet. <br />10-foot wide rock bed 50 feet long = 500 square feet <br />CONSTRUCTION EQUIPMENT: <br />A rubber-tired tractor may be used for plowing or disking to prepare the soil surface but in no <br />case shall a rubber-tired tractor be used after the surface preparation is completed. A crawler <br />or tract-type tractor shall be used for mound construction. <br />SOIL SURFACE PREPARATION: <br />The discharge pipe from the pump to the mound area shall be installed prior to soil surface <br />preparation. The trench excavated to install. the discharge pipe shall be carefully backfilled and <br />compacted to prevent seepage of effluent. <br />PAGE2