My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Narrative
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1400 Bracketts Point Road - 11-117-23-32-0025
>
Land Use
>
18-3998, VAC
>
Submittal
>
Narrative
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2026 12:57:55 PM
Creation date
3/19/2026 12:57:51 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lake. The present sewer line will be abandoned in place per the direction of the City <br />Engineer.; the existing easement, Block 1, Lot twill be vacated- <br />0 b ,later- Each private residence will have their own private well for their water supply, <br />installed at the time of residence construction. There are presently two wells on the <br />property; one serving the existing residence and one serving the caretakers' <br />residence. The well serving the current residence will be retained and the additional <br />well will also be retained, until a residence design is provided, for possible use on <br />that lot; if the additional well cannot be used due to home designipad location then <br />that well will be abandoned per MDH well abandonment procedures. <br />0 Site grading!- As shown on the Preliminary Plat, Site grading will be completed for all <br />development areas. <br />0 Storm water management- This is a Tier 1 site; storm water management will be <br />completed on -site. <br />Small utilities- A joint trench for electric, gas, telephone, and cable is planned along <br />the new road ROW with the current joint trench utilities along the existiray iifuauway <br />abandoned in place, subject to utility company designs. <br />® '�;Iletland delineation- The required wetland delineation has been completed; both <br />COE and MCWD have issued a NO WETLANDS DETERMINATION, COE by letter, <br />MCWD verbally. <br />0 Conservation design- The required Conservation Design analysis by Kjolhaug <br />Environmental Services is as noted in enclosure 6). The significant tree inventory is <br />presented in survey and tabular form with individual tree locations is noted on the <br />Preliminary Plat. <br />® Pdvate docks/boat slips- The individual property owners will be responsible for <br />obtaining their permits from the LMCD and for complying with all regulatory <br />requirements for individual docks for their lakeshore property. <br />Lakeshore foot SetE �a— X- Representative building pads are as shown on the plan to <br />protect Line of Sight for adjacent lots along the lakeshore and to establish an <br />average lakeshore setback. <br />42 Lot ceta'sls- <br />o Lot 1- 3.36 +/- acres; the existing residence will be retained. <br />o Lot 2- 2.06 +/- acres, possible house as noted; the existing tennis court/pool <br />may be removed along with the path and replaced with grass. <br />o Lot 3- 2.35 +1- acres, possible house area as noted; the caretakers house will <br />be removed along with associated out buildings and replaced with grass. <br />o Lot 4- 2.10+1- acres, possible house area as noted; the driveway access to <br />the existing residence will be removed and replaced with grass. <br />o Lot 5- 2.41 +1- acres, possible house are as noted. <br />1-7iscellaneours- <br />o Training -The caretakers' house on Lot 3 will be removed. Prior to the <br />demolition, an opportunity for training in the structure by the Orono Police <br />Department and the Long Lake Fire Department exists. The details can be <br />determined after Final Plat approval and prior to the commencement of <br />construction. <br />o Water Reservoir- There is a large underground water storage tank (UST)\ <br />serving Lot 1 intended to supplement the fire tanker capacities, for private <br />insurance purposes. This UST and associated hydrant, piping and ventilation <br />
The URL can be used to link to this page
Your browser does not support the video tag.