My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Project Packet
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1645 Bohns Point Road - 17-117-23-11-0007
>
Land Use
>
90-1507, VAR
>
Project Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2026 10:51:13 AM
Creation date
3/17/2026 10:49:50 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3302-3303 UNIFORM BUILDING CODE <br />The maximum occupant load for an assembly use shall not exceed th--,occupant <br />1.,ad as determined to accordance with Section 33021a1. <br />EXCEPTION: The occupant load for an assembly building or portion thereof <br />stay be increased, A hen approved by the building official. if all the requirements of <br />this cafe are met for Such increased number tit persons The building official may <br />require an approsed aisle. sealing ur fi xed egwpinent Jiagram to substantiate such an <br />incre..se, and may reoluire that such diagram he p,isied <br />1c► Posting of Room Capacity. Any room havinv an occupam load of Su or <br />more where fix_d seats are not installed, and which is used for classroom. <br />assembiv or similar purpose. shall hasz the capacity of the room posted in a <br />conspicuous plat- on An approved st i the main exit from the room. Such <br />signs shall be maintained legible by the owner or his authonzed agent and shall <br />indicate the number of occupants permitted for each room use. <br />1 d I Revised Occupant L^ird. After a budding is occupied. any change �n use or <br />increase in occupant load sl,a.' .:ampl% with ihu ,:haptec See Section 502. <br />Exits Rtaquired <br />Sec. 3303.1 a ► Number of E xiti. Every buildings or usable portion thereof shall <br />rM I <br />have at least one exit, not :ess than two exits where required by Table No 33-A <br />and additional exits as required by this subsection. <br />For purposes of this section, basements and occupied roofs shall be provided <br />with exits as required for stones <br />Floors complying with the provisions for mezzanines as specified in Section <br />1-1 1b shall be pt.ivided with exits as specified therein <br />The second story shall be provided with not less than two exits when the <br />00. Upant load is 10 or mor- <br />EXCEPTIONS: I Except as provided in table No t ,-A onls zinc exit need be <br />provided from the second stor} within an ...dividual dwelling unit Reter to Section <br />1204 for emergency escape or rescue requirements fro:ii sleeping nx,ms <br />Two or more dwelling units (in the second story may hale access io only one <br />common exit when the total occupant load does not exceed IU <br />(kcupants on tloorn above the second scary and in basements sha;I have access <br />to not less than two separate exits from the floor or basement. <br />EXCEPTIONS: I Floors and hase►nents used exclusrsch for ser%ice of the <br />building may have one exit For the purpo ws of this exception, storage ruuins <br />laundry rooms. maintenance offices and similar uses %hail nut br .onsidered as <br />providing service to the building <br />I Basements *,thin an utdisidual dwelling unit havini an oLcupant load of less <br />than 10 may have one r x i i <br />3 Storage rooms, laundry mor,u and maintenance oiticcs not ex,eeding k)t) <br />square feet in fkxw area may be prosided w ith only one exit <br />a Ck-cupied rit"s tin Group R. Di%I%K►n i i.kcupartcies mas have iKie exit if such <br />occupied areas are less than SW square nett heated no higher rhan immedia.ely <br />Above the second story <br />For special requirements we the following sectuxis. 6coup A. Sections 3 z 17 <br />and 3318, Group E. Section 3319-. Group H. Section 3320. Group 1. Section 3321. <br />Rooms Containing Fucl-fired Equipment and Cellulose Nitrate Handling Rooms. <br />
The URL can be used to link to this page
Your browser does not support the video tag.