My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Project Packet
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1635 Bohns Point Road - 17-117-23-11-0006
>
Land Use
>
10-3481, VAR renewal
>
Project Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2026 2:05:54 PM
Creation date
2/26/2026 2:04:26 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STOAI~"') Stork Twin City Testing Corporation <br />Materials Technology <br />Proposed New Residence at 1635 Bohns Point Road <br />Orono, Minnesota <br />Stork Twin City Testing Corporation Project #TCT006405P <br />Page 8 of 11 <br />In our opinion the final lowest floor slab elevation should be a minimum of 4' above the <br />highest recorded water level elevation at the site. We recommend that a vapor barrier <br />be placed beneath the floor slab. The vapor barrier edges should be taped with the <br />barrier at the perimeter walls to run vertically up the walls prior to slab placement. This <br />vapor barrier is recommended to minimize water vapor migration through the floor slab <br />concrete. Water vapor can adversely affect floor coverings proposed for the residence. <br />We recommend an interior and exterior drain tile system be installed to pick up <br />groundwater moisture from beneath the slab. The drain tile system should be installed <br />below floor grade on the outside and inside of the foundation wall and should be <br />surrounded by at least six inches of washed, coarse aggregate material which is <br />enveloped in a geotextile fabric. We also recommend some lateral runs of draintile be <br />installed in general floor slab areas. The drain tile should be connected to a suitable <br />outfall or sump where water can be discharged from the system. We are including a <br />typical exterior drain tile system sketch attached to this report. The foundation walls <br />should also include a water-proofing system to prevent water infiltration into the slab-on- <br />grade subgrade soil. <br />4.5 Underground Utilities <br />The soils encountered in the borings near the surface may require some reworking to <br />support typical buried utilities. If loose/soft soils are encountered in the bottom of utility <br />trenches, some subcutting or recompaction of the soils will be required. This may <br />include subcutting to allow for placement of geotextile fabric and 1' of compacted utility <br />bedding. Fill placed as utility bedding should be either crushed rock or clean, well- <br />graded granular soil. Due to the high water table as depicted by the soil boring, <br />dewatering will more than likely be required during utility construction to the new <br />structure. <br />Information and statements in this report are derived from maleriat, information and/or spcclflcanons rumished by the client and exclude any ex.pressed or implied warranties as to tile fitness of the material tested <br />or analyzed for any particular purpose or use. This certificate or report is the conlidenUa! property of our client and may not be used for advertising purpose:s. This certificate or report shall not be reproduced <br />except in full, wilhout wnlten approval of this taboralory and shall be signed or olhei-wlse approved by aulhorized staff members only. The recording of false. fictitious or rrau<tulent statements or entrtes on this <br />document may be punished as a felony under Federal Statues including Federal Law TILie 18, Chapter 47. This doc:ument conlalns technical da1a whose export and re-export/re-transfer is ~ubjecl lo control by <br />the U.S. Oepar1ment ot Commerce under lhe Export Administration Acl and the EXpOrt Administration Regulaticms. TI1e depanment of Commerce's prior writtt'!n approval Is required for lhe export or re.exportlre- <br />lransfer of such technical information to any foreign pere:on, foreign enUly or foreign organization whether in U,a UnUed states or abroad. EAR~CONTROLLED DATA.
The URL can be used to link to this page
Your browser does not support the video tag.