Laserfiche WebLink
r x 1 CITY of ORONO <br />Municipal Omces <br />1� <br />J: ���ti0�6 Street Address: Mailing Address: <br />4lrEgHp�� 2750 Kelley Parkway P.O. Box 66 <br />—� Orono, MN 55356 Crystal Bay, MN 55323.0066 <br />r ��%hn �l//►� Address: 793 Ferndale Rd. N. <br />Owner: �. l�)/l�Qi1GP <br />Permit k's: 491 Dates: 11/23/87 Contractors: Ingleside Engr. <br />(This is (Y-- an existing system ( ) new construction). <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />0 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottom <br />of the drainfield and the saturated soil level. <br />(The saturated soil level is E>4 or is not ( ) identified under this s•vtic system. If the <br />saturated soil level is not identified, this classification is subject to revision.) <br />TANK CONDITION (5-9): 9 <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed new. <br />0 Inspection pipe is located over tank baffle -can not measure solids accumulation. Ittanks <br />have not been pumped out within three years, they should be pumed out now. <br />10 One or more tanks c means the septic system is non-com ant. <br />(The tanks are [ 7 or are not i ) water tight or the condition is (X) unknown. 'f the tanks <br />are not confirmed to be watertight, this classification is subject to revision.) <br />D CONDITION (11nos 11 ` <br />1 Drainfield is dry, no surfacing evident. <br />2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE• (system age and condition, soils, etc.): medium <br />COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br />were performed to verify a 3 foot separation between the drainfield and the seasonal water <br />table. The separation is 1.7 feet and the system is non -compliant. Repair or replacement of <br />the septic system is required by 12/31/2005. <br />Date of Inspection S tic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tekphone (612) 473-7357 a FAX 4734510 <br />