My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-10-15 Septic System Review
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
793 Ferndale Road North - 36-118-23-12-0016
>
Septic
>
1992-10-15 Septic System Review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2026 3:31:00 PM
Creation date
2/12/2026 3:26:53 PM
Metadata
Fields
Template:
x Address Old
House Number
793
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
793 Ferndale Road North
PIN
3611823120016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subdivision #1762, Septic Review <br />October 15, 1992 <br />Page 2 <br />LOT 1, BLOCK 1 - WEST ONE-HALF <br />Soil testing and septic system design has been provided for <br />a 5-bedroom home including primary and alternate drainfield <br />sites. Both sites meet MPCA Rules Chapter 7080, however a 25' <br />section of the alternate drainfield site encroaches within the <br />20' setback required for driveways. The proximity of the <br />driveway to the alternate site cannot be avoided due to site <br />limitations. Driveway specifications should be provided to show <br />that drainage will not adversely effect this site. <br />Due to the proximity of the access road to the septic sites, <br />snow fencing will be required around both drainfield sites prior <br />to the issuance of final plat approval. Specific septic system <br />details are included below: <br />- Depth of seasonal saturation (mottling) is 1' 2" to 3' <br />6", requiring a mound. <br />- Slope at the primary and alternate drainfield sites is <br />up to 5%. <br />- Percolation rates average 6.2 minutes per inch at 12". <br />- A 10' driveway setback variance will be required for <br />the alternate site. <br />SUMMARY <br />The site inspection revealed several concerns regarding <br />drainage around the drainfield sites due to the existing driveway <br />for he east lot as well as the proposed driveway for the west <br />lot. Additional information will be required regarding the <br />proposed driveway to ar a that a 10' setback from both the <br />existing system for the lost lot and the proposed alternate <br />system for the west lot is feasible as well as to assure that it <br />is possible to drain the driveway away from both of these septic <br />sites. The alternate drainfield site for the existing residence <br />will also be required to assure that drainage can be directed <br />around this site from the existing driveway. <br />Provided that acceptable information can be provided <br />regarding these drainage questions, staff is comfortable with the <br />septic plans provided. One condition of the subdivision must be <br />that both the existing and proposed drainfield sites must be <br />staked using snow fencing to prohibit any traffic from compacting <br />these sites. The fencing must be installed prior to the granting <br />of a final plat approval and any motorized travel across these <br />areas. <br />lsv <br />
The URL can be used to link to this page
Your browser does not support the video tag.