Task# 98759 Date Ca lled in 1--D-a_t_e _S_c_h_e_d_u _le -d---+�l �0--=9 -_2�5�------1 <br />City Of Orono Rescheduled 11-3-25 <br />Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form <br />Property Address: 3405 Crystal Ba Road <br />PID: 1711723440022 <br />Owner Information <br />Name: Catherine Sweet <br />Mailing Address: 5016 92nd Crescent <br />(if different from Brooklyn Park, MN 55443 Property) <br />Phone: 612-210-7995 I Email: I sandral uesse3 2 l@gmail.com <br />Inspector Information <br />Name: <br />Company/ Organization cny or urono <br />Highview Plumbing License number: <br />Phone: 952-249-4686 I 6 I 2-916-1685 Email: <br />Inspection <br />System Standard Pass <br />Roof Drains Roof drains and leaders Roof drains should not be connected to the sanitary sewer but should discharge to the ground outside of a building. If the roof � drains are connected to the sanitary sewer, disconnect them, plug any open connections to the sanitary sewer using a non-shrink permanent material, and <br />redirect the roof drains onto the ground outside the building, <br />Foundation Foundation drains are underground pipes that collect storm water from <br />Drains around the base of a building and into a sump basket, where it is then <br />pumped outside of the building. Foundation drains should not be connected � to the sanitary sewer. <br />Sump Pumps Sump pumps are designed to capture smface or ground water that enters <br />basements or crawl spaces and pump it away from the house. The basic sump <br />system includes drain tile, a sump pit, a sump pump, a float or switch, and a � drain line. Sump pumps should not be connected to the sanitaty sewer. <br />Sewer Service Sanitary Sewer Inflow & Infiltration (I/I) Compliance Inspection Sanita1y <br />Line Sewer Lines. All sanitaiy sewer lines serving Property, from the house to the main line, shall be in a safe and functional condition and shall be free from all � leaks, failures including but not limited to partially collapsed sections or tree root intrusion. The sanitaty sewer lines shall meet the City Code standards and specifications. (Details on back of this sheet) <br />Notes: <br />Toilet Removed <br />For Inspection: <br />o Yes <br />Inspectors Signature: <br />Owners Signature: <br />Certificate of Com liance E <br />oNo <br />I Date: <br />I Date: <br />City Review <br />D Corrective Action Re uired <br />Fail <br />Replaced 20" with 4" sch 40 pvc at the 6x4 connection. Glued the 6' into existing & <br />used a strong back fernco from 4" pvc to 4" cast. Approved by Jimmy Nelson, <br />Supervisor of Sewer & Water