1995-05-30 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
627 Ferndale Road North - 36-118-23-11-0029
>
Septic
>
1995-05-30 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2026 9:48:26 AM
Creation date
2/4/2026 9:44:12 AM
Metadata
Fields
Template:
x Address Old
House Number
627
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
627 Ferndale Road North
PIN
3611823110029
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO <br />Municipal Offices <br />Post Office Box 66 <br />Crystal Bay, MN 55323-0066 <br />ON —SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />Owner: Address: j1 ! icilrala/G Iw-/Litr <br />Permit #' a- Dates: 13q ZUc Contracture: 4 1K--6n ka <br />City ordinance rxanber 100 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. <br />The on -site sewage treatment system at the above address has been inspected and appears to fall into the category <br />checked below. <br />(This is lA an existing system [ 7 new construction) <br />"CODE SYSTEM" -A system which meets all the location, .esign, and construction standards of the current City <br />Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br />without discharging any pollutants into ground or surface waters. <br />"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction standards of the <br />current City Codes, but was 4nstalled according to the code in effect at the time of installation, and which <br />is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br />any pollutants into ground or surface waters. <br />"NON -CONFORMING SYSTEM" -A prohibited system; a system located within a designated 100-year floodplain; any <br />system which may or may not meet ell the location, design, and construction standards of the current City <br />Codes and which is failsrq for any reason; and any system with less than 3 feet of unsaturated soil or sand <br />between the distribution device and the limiting soil characteristics. <br />(The limiting soil characteristic � has or I I has not been identified at this time. If the limiting soil <br />characteristic has not been identi1ied, this classification may be subject to revision.) <br />Tank inspection indicates: <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future proble. <br />7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possiblemms <br />. <br />B System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br />9 Inspection risers missing -tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br />tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br />out now. <br />0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br />If tanks have not been pumped out within the last three years, 20 s ould be pumped out noQffw� <br />1Nr1_1LX> <br />DRAINFIELD CONDITION (11-14): <br />D�field inspection indicates: <br />11 Drain field is dry, no surfacing evident. <br />Sane evidence of surfacing, not critical yet. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />LIMITING SITE FACTORS (slope.setbacks.etc.): <br />POTENTIAL FOR SYSTEM FAILURE (depends on so Ov,- ter table.etc.): <br />COMMENTS: <br />Date of Inspection <br />Note: In the event that this inspection report is used to <br />property, be advised that this report does not guarantee <br />properly, but is merely an opinion of the adequacy of <br />information. <br />ystem inspector <br />satisfy the requirements for a mortgage or other transfer of <br />or certify that an existing system will continue to function <br />the system under current conditions based on the available <br />This report must be kept on the premises with the system location and pumping records. <br />WHITE COPY Inspectors FIN YELLOW COPY Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.