Laserfiche WebLink
Oil llir Aorth abort' t I <br />Like tfifn a onka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX i6 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 553 :3 <br />473.7357 <br />OWNER VnSOrl — ADDRESS _ L Pr Zee � ei <br />PERMIT NO.'S. — DATES 1 /!J e ---- CONTRACTORS <br />City Ordinance No. 210 requires that each on -site sewage treatment system m Oros,•, he inspected on a regular bans. T e on -site sewage <br />treatment system at the above address has been inspected and appears to fall into the ategory checked below <br />(This is Z an existing system ❑ new construction) <br />21 Meets or exceeds current City standards in all respects relating to (it igo. construction, and location. Appw : to be operating <br />properly. <br />2 Does not meet all current City standards for new construction (1978 Code) but in most respects appear to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning p )party, no major <br />upgrading of the system is required at this time. <br />❑ 3 Does not meet cufra-r C,ty standards in many respects relating to design, construction, or location. Appe: s to be operating <br />adequately it this time, but has a relatively high potential for future problems No major upgrading of sy. ern is required at <br />this time. <br />4 System may or rimy not meet current C+:y standards for design, consituruon or location, but is fai.ing to wroperly treat and <br />dispose of the current input, and is endangering a water supply, o• is a source of pollution to surface or, oundwaters. or is <br />creating a safety harard, or is otherwise creating d public nuisance. Please contact the City Inspector to dis uss system repair/ <br />replacement procedures. If drainfield replacement is necessary, sod testing will usually be reqi tied, and a r esign and site plan <br />must be submitted for review Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( m Checked items may require your action) <br />Tank inspection indicates <br />❑ Pumpout not needed at this time, <br />Iff Solids accumulation in tanks indicates they should be pump- <br />ed out this year to help prevent future problems <br />❑ Solids accumulation in tanks is at a critical level, Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection -sets missing —tanks could not be inspected. <br />Inspection risers (4" dia. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />SITE : HARACTERISTICS <br />Limiting Site Factors <br />C Slope <br />❑ Soil <br />❑ High water table <br />❑ Lot size <br />❑ Lake, wetland, or stream <br />❑ Drainage <br />COMMEN rS <br />Date of Inspection <br />❑ Inspection pipe is located directly over tank waffle. (Does not <br />give accurate measurement of solids accufr ilation.) If tanks <br />have not been pumped out within the last hree years, they <br />should be pumped out now. <br />Drainnfield inspection indicates <br />0 Drainlreld is dry, no surfacing evident. <br />❑ Some evidence of surfacing, not critical yet <br />❑ Dramfield is .iturated and visibly disc arging untreated <br />effluent to the surface. This condition m. v require replace- <br />ment or additions to dramfield Contact )e City Inspector <br />--t . iediately. Repairs must be completed % :hin 90 days. <br />❑ Drarnfield extent and condition unknown. <br />Potential for System Failure <br />Sitr :apabihties for <br />(depends on soil types, water <br />Fat re Expansion <br />table, dnd system conditroci <br />tAdequate <br />54 Low <br />l r Fan <br />❑ Medium <br />Poor <br />❑ High <br />L Inadequate <br />❑ System is causing visible <br />surface discharge. <br />Septic System Inspector <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property. L advised that <br />This report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of hp adequacy <br />of the system under current wnditions based un the available intoirnation <br />This report must be kept ­i tie pfewise..nth system lut on and pumping records <br />WHITE COPY ! Inspector's File GOLD COPY i Homeowner <br />