Laserfiche WebLink
� ... F CITYdORONO <br />Munkipal ORkes <br />2750 Kelley Parkway ,x 66 <br />Orono, MN 55356 Crystal Bay, MN 55323.0066 <br />i <br />Owner: �� Address: 555 Ferndale Rd. N. <br />Permit k's: 1565 tes: 10/36/47 Contractors: Sullivan <br />(This is [X) an existing system [ ) new construction). <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />Compliant System: Does no* meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />© codes and is functioning properly. <br />Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feQL of vertical separation between the bottom <br />of the drainfield and the saturated soil level. <br />(The saturated soil level is r}'] or is not ( ) identified under this septic system. If the <br />saturated soil level is not ident fied, this classification is subject to revision.) <br />TANK CONDITION (5-9): 9 <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed now. <br />Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />10 one or more tanks are cesspools, which means t ee septic system is non -comp— K ant. <br />(The tanks are t 1 or are not i ) water tight or the condition is 1)4 unknown. If the tanks <br />are not confirmed to be watertight, this classification is subject to revision.) <br />INFIELD CONDITION (11-14): 11 <br />11 Grainfield is dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and conditi-n unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): high <br />COMMENTS: The septic system is non -compliant, but does not appear to pose an imminent threat to <br />public health or safety (surface discharge or backup into the dwelling). The system must be <br />repaired or replaced by 12;31/2002 or within ninety days of posing an imminent threat to public <br />health or safety, whichever comes first. <br />Date of Insp_cb ticn <br />-§6TDtfe System I pector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tek *wm (612) 473.73S7 a FAX 473-NIO <br />