Laserfiche WebLink
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />Ott Hit, :Vortb Sbore of <br />Lake Alinneto►tka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 5v323 <br />473-7357 <br />i I I <br />OWNER r' f . f lit r r�1.- ! I, C_ ADDRESS � i � %��>1 44 <br />PERMIT NO.'S. <br />DATES <br />CONTRACTORS <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage <br />beatenent system at the above address has been inspected and appears to fall into the category checked below. <br />(This is CR an existing system ❑ new construction) <br />1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />02 Does not meet all current City standards for new construction 11978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />3 Does not meet current City standards in many respects relating to design, construction, or location. Appesis to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />Q4 System may or may not meet current City standards lot design, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or Woundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be requited, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION I [Z Checked items may require your action? <br />Tank inspection indicates'. <br />❑ Pump tit not needed at this time. <br />Solids accumulation in tanks indicates they should be pump- <br />ed out this yaw 10 help pro'.:nt future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risers missing —tanks could not be inspected. <br />Inspection risers (4" die. pipe) must be installed in each tank <br />at next purnpout If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />❑ Slope <br />❑ Soil <br />❑ High water table <br />® Lot sire <br />❑ Lake, wetland, or stream <br />❑ Drainage <br />COMMENTS: l CA a I K- J <br />❑ Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspection indicates: <br />ir," . i•., ..� ckrar, <br />L <br />U Drainfield is dry, no surfacing evident. � � � f <br />❑ Some evidence of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent to the surfs". This condition may require replace- <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />❑ Drainfield extent and condition unknown. <br />Potential for System Foiture <br />(depends on soil types, water <br />table, and system condition) <br />F! Low <br />W Medium <br />® High <br />❑ System is causing visible <br />surface discharge. <br />ro liv r I I •Iwo <br />Site Capabilities for <br />Future Expansion <br />❑ Adequate <br />IR Fan <br />❑ Poor <br />❑ Inadequate <br />r <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the available information <br />This repot t must be kept on the premises with system location and pumlwiq records <br />WHITE COPY i Inspector's File GOLD COPY r' Homeowner <br />