Laserfiche WebLink
Oil tlhr \n1Y/1 Shun• oJ. <br />Lake iltitn ironkr1 <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />O R 1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473.7357 <br />OWNER �Fly/S /`�^ ADDRESS�e—Lt_1[/s___ <br />PERMIT NO.'S. - DATES17--- CONTRACTORS At��IorCityOrdinance No. 210 requires that each on -site sewage treatments stem in Orono be inspected on a r ular <br />4e ve9 basis. Title o -s to sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This is 10 an existing system ❑ new construction) <br />1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />❑ 3 Does not meet current City standards in many respects relating to design, construction, or location. Appeals to be operating <br />adequately at this time, but has a relatively high potential for fulute problems No major upgrading of system is required at <br />this lime. <br />ED4 System may or may not meet current City standaws for destgn, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwateis, or is <br />creating a safety haraid, or s otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If dramheld replacement is necessary, sod testing will usually be requited, and a design and site plan <br />must be submitted (or review. Your contractor must obtain a permit before work is started <br />ZYSTEM CONDITION 1 I>a Checked items may require your action) <br />Tank inspection dicates: ❑ Inspection pipe is located directts over tank baffle. (Does not <br />❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) II tanks <br />❑ Solids accumulation in tanks indicates they should be pump• have not been pumped out within the past three years, they <br />ed out this year to help prevent future problems. should be pumped out now. <br />❑ Solids accumulation in tanks is at a critical level- Tanks Drainfield inspection indicates <br />shoulu be pumped out as soon as possible. Z Drainfield is dry, no surfacing evident. <br />❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing, not critical yet. <br />within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated <br />Inspection risers missing --tanks could not be inspected. effluent to the surface. This condition may require replace - <br />Inspection risers 14" dia. pipe) must be installed in each tank ment or additions to drainfreld. Contact the City Inspector <br />at next pumpout. If tanks have not been pumped out within immechatek,-. Repairs must be completed within 90 days. <br />the last three years. they should be pumped out now. ❑ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />❑ Slope <br />Cl Soil <br />❑ High water table <br />❑ Lot sire <br />❑ Lake, wetland, or stream <br />❑ Drainage <br />COMMENTS <br />:•rle Capabilities for <br />Future Expansion <br />❑ Adequate <br />Fair <br />O Poor <br />❑ Inadequate <br />Potential for System Failure <br />(depends on soil types, water <br />table and system Londitronl <br />Low <br />El Medium <br />n High <br />11 System is causing visible <br />surface discharge. <br />Note In the event that this inspr . lion report is used to satisfy the requirements for a mortgage or other transfer of property tie advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely at, opinion of the adequacy <br />of the system under current conditions based on the available information <br />This repx • rtiurst tx• kept on the premises with system location and pumping records <br />WHITE Ct )P't Inspeclor's Far GOLD COPY / Humtwiwner <br />