1990-01-29 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
455 Ferndale Road North - 36-118-23-14-0013
>
Septic
>
1990-01-29 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2026 9:43:29 AM
Creation date
1/21/2026 9:27:07 AM
Metadata
Fields
Template:
x Address Old
House Number
455
Street Name
Ferndale
Street Type
Road
Street Direction
Norht
Address
455 Ferndale Road North
PIN
3611823140013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1* - - .: .1 <br />.�-P TES TING.). NC. D <br />951 v',TYDID LAVE <br />ST. MICNA-'_, MN 55376 <br />497.3566 <br />,;_even 3. Schirmers <br />Lauer Homes, Inc. <br />Lot 2, Block 1, Houser, Lauer <br />wayT to Country Club Add. <br />Oreho, Henn. Co., MN <br />A 3 0 890 ►; I <br />January 29, 1990 <br />op <br />' �._ , , `' � raj'/• • ..��,, <br />This system is Designed for a Type 1, six bedroom home and in accordance <br />with the Minnesota Pollution Control Agency Chapter 7090 and local <br />ordinances. <br />The soil was frozen to a depth of 18". The frost was removed by the <br />builder with coal heat for 72 hours. <br />The soils on this site are typical of SCS soils mapped - HcC2 - Hayden <br />clay loam. A seasonally high water table was located at 12", 16", <br />18", 26" t 30", (mottled soil). Due to the seasonally high water table, <br />a pressurized mound system will need to be installed. The bottom of <br />the rock bed must be located at least 3' above the seasonally high <br />water table. <br />The soils at a depth of 12" & 18" have a percolation rate averaging <br />17.0 min/inch and are adequate for treating septic effluent. <br />A pumping chamber will need to be installed to lift the effluent to the <br />treatment area. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall lave their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must be turned over, just break up the sod, be sure <br />not to over work. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must be turned over, just break up the sod, be sure <br />not to over work. <br />All neighboring wells are located more than 100' away from the proposed <br />treatment area. <br />Keep all heavy equipment off of the proposed treatment area before and <br />after construction as much as possible. The treatment area should be <br />marked off before construction. <br />Soil and Percolation Tests CONT' D <br />Septic SYltern Design <br />