Laserfiche WebLink
FOUNDATION PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />1 <br />S1 <br />REFERENCE PLAN <br />CONCRETE PAD FOOTING SCHEDULE <br />MARK FOOTING SIZE REINFORCEMENT EACH WAY <br />F1 2'-0" x 2'-0" x 0'-8"NONE <br />F2 2'-6" x 2'-6" x 0'-8"#5 BARS @ 12" O.C. <br />LOCATE REINFORCEMENT 3" FROM THE BOTTOM OF FOOTING <br />F2 FOOTINGS MAY BE 12" THICK UNREINFORCED <br />F2 <br />20" WIDE x 8" DEEP <br />CONCRETE STRIP <br />FOOTING TYP. AT <br />INTERIOR BEARING <br />AND STAIR WALLS <br />PROJECT SCOPE <br />DESIGN OF CAST-IN-PLACE CONCRETE, STEEL, AND WOOD FRAMING FOR A PROPOSED SINGLE-FAMILY RESIDENCE. <br />CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESE DRAWINGS, STANDARD INDUSTRY PRACTICE, AND THE <br />REQUIREMENTS OF THE CODE. <br />GENERAL NOTES <br />1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED BY ESKUCHE DESIGN GROUP <br />LAST DATED 10-24-24 FOR MORE INFORMATION. <br />2.IT IS THE RESPONSIBILITY OF THE BUILDER TO PROVIDE ALL FUTURE PLAN OR FIELD CHANGES TO THE HANSON GROUP <br />FOR REVIEW. PROVIDE FINAL TRUSS LAYOUTS TO THE HANSON GROUP PRIOR TO CONSTRUCTION AND MATERIAL <br />ACQUISITION. <br />3.ADEQUATE SHORING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. <br />4.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH WORK. <br />NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE. <br />5.MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />FOUNDATION NOTES <br />1.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN <br />ACCORDANCE WITH THE CODE. <br />2.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHIN 12" OF EACH END AS <br />APPLICABLE. <br />3.BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. PROVIDE 48" MATCHING HOOK BARS FOR ALL <br />HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. <br />4.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT. <br />5.BACKFILL BELOW EXTERIOR PATIO SLAB WITH COMPACTED GRANULAR MATERIAL TO FROST DEPTH (4'-0" MINIMUM). <br />6.PRIOR TO BACKFILLING, HOUSE FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED BY FLOOR SYSTEM AT TOP AND <br />SLAB AT BOTTOM OR BY ADEQUATE TEMPORARY BRACING. <br />7.RETAINING WALL TYPE FOUNDATION WALLS RELY ON SLAB-ON-GRADE FOR LATERAL SUPPORT. ADEQUATE TEMPORARY <br />BRACING IS REQUIRED UNTIL SLAB IS PLACED AND CURED. BULKHEAD STEP ALL RETAINING WALL STYLE FOOTINGS. DO <br />NOT JUMP FOOTINGS AT THESE LOCATIONS. <br />8.SLAB TO BE INSTALLED TIGHT TO CONCRETE WALLS. IF INSULATION IS INSTALLED BETWEEN SLAB AND WALL, MUST BE <br />ASTM C578 TYPE V (100 PSI COMPRESSIVE STRENGTH). <br />9.SITE ELEMENTS INCLUDING LANDSCAPING RETAINING WALLS ARE NOT INCLUDED IN THE SCOPE OF THESE DRAWINGS <br />UNLESS SPECIFICALLY NOTED. <br />FRAMING NOTES <br />1.ALL HEADERS ARE TO BE MINIMUM (2) 2x10 LUMBER UNLESS NOTED OTHERWISE. (2) 2x10 MEMBERS SHOWN MAY BE <br />SUBSTITUTED WITH (2) 1¾"x7¼" LVL OR (3) 1¾"x5½" LVL AS REQUIRED. <br />2.ALL DIMENSION LUMBER HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE BEARING STUD AT EACH END AND TWO <br />AT INTERMEDIATE SUPPORTS. ALL 2-PLY LVL AND GIRDER TRUSS MEMBERS ARE TO HAVE A MINIMUM OF TWO BEARING <br />STUDS AT EACH END AND AT INTERMEDIATE SUPPORTS. 3-PLY LVL AND GIRDER TRUSS MEMBERS ARE TO HAVE A <br />MINIMUM OF THREE BEARING STUDS AT EACH END AND AT INTERMEDIATE SUPPORTS. ADDITIONAL BEARING STUDS ARE <br />NOT REQUIRED FOR LVL SUBSTITUTED FOR STANDARD SAWN LUMBER. ALL BEARING ABOVE IS UNLESS NOTED <br />OTHERWISE ON PLANS. TRUSS SUPPLIER IS TO VERIFY GIRDER TRUSS BEARING LENGTH AND SUPPORT REQUIREMENTS. <br />3.ALL HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE FULL HEIGHT KING STUD AT EACH END. EXTERIOR <br />OPENINGS GREATER THAN EIGHT FEET IN WIDTH ARE TO HAVE A MINIMUM OF TWO FULL HEIGHT KING STUDS AT EACH <br />END, EXCEPT AT TALL WALLS AS NOTED. EXTERIOR OPENINGS GREATER THAN FOURTEEN FEET IN WIDTH ARE TO HAVE <br />A MINIMUM OF THREE FULL HEIGHT KING STUDS AT EACH END, EXCEPT AT TALL WALLS AS NOTED. FOR CONTINUOUS <br />BEAM CONDITIONS, SPAN IN DETERMINING NUMBER OF KING STUDS IS THE FULL LENGTH OF THE HEADER. <br />4.ALL CONNECTIONS ARE TO BE MADE WITH ADEQUATE SIMPSON, USP OR EQUAL JOIST HANGERS, CLIPS, POST CAPS, AND <br />POST BASES. <br />5.CONNECT MULTIPLE MEMBER LVL'S TOGETHER IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. <br />6.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICH MEETS <br />OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4 WSP AND CS-WSP. <br />A.2x6 STUDS SPACED @ 16" O.C. <br />B.WALL SHEATHING: 7 16" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12" <br />O.C. AT INTERMEDIATE SUPPORTS OR 13 4" 16 GAUGE STAPLES @ 3" / 6" SPACING. <br />7. ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O. <br />A.2x4 OR 2x6 STUDS SPACED @ 16" O.C. <br />B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. OR TYPE <br />S/W WALLBOARD SCREWS @ 16" O.C. MAX. (5 8" MINIMUM STUD PENETRATION) <br />8. ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA. <br />A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C. <br />B.FLOOR SHEATHING: 3 4" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12" <br />O.C. AT INTERMEDIATE SUPPORTS. VERIFY IF HOUSE PLANS REQUIRE THICKER MATERIAL. 118" PLYWOOD OR <br />WARMBOARD WILL REPORTEDLY BE USED ON THE MAIN LEVEL. <br />9. ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA. <br />A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C. <br />B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH USP RT7 OR SIMPSON H2.5 CLIPS OR EQUIVALENT AND (4) 0.131"Ø <br />x 3" TOENAILS. <br />C.ROOF SHEATHING: 12" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12" <br />O.C. AT INTERMEDIATE SUPPORTS. VERIFY IF ROOFING OR HOUSE PLANS REQUIRE THICKER MATERIAL. LOW SLOPE <br />ROOFS TO HAVE 3 4" MIN. STRUCTURAL PANEL SHEATHING. <br />D.PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES AT ENERGY HEELS OR TOP AND BOTTOM BLOCKING SHEATHED <br />PER FRAMING NOTE 6. BLOCKING TO EXTEND FROM WALL TOP PLATES TO WITHIN 2" OF ROOF SHEATHING. <br />10. ALL BEARING POINT OR POST LOADS ARE TO BE BLOCKED SOLID TO THE FOUNDATION. SQUASH BLOCKING TO BE 2x8 <br />MATERIAL AT OVERHUNG PLATES, EXCEPT AT PSL LOCATIONS. <br />11.STEEL BEAMS ARE TO HAVE SOLID 2 x MINIMUM TOP PLATE FASTENED WITH ½" DIAMETER BOLTS STAGGERED EACH SIDE <br />OF WEB AT 48" ON CENTER MAX. WIDTH TO MATCH BEAM. INCREASE PLATE THICKNESS AS REQUIRED FOR TOP FLANGE <br />HANGERS. BEAM TOP FLANGE / PLATE TO BE BRACED LATERALLY BY FLOOR SYSTEM AT 48" O.C. MAX AND AT ENDS TYP. <br />12.FOR JOIST TO FLUSH STEEL BEAM CONNECTIONS, BLOCK WEB SPACE SOLID w/ LUMBER TIGHT BETWEEN FLANGES AND <br />BOLT THROUGH WEB w/ 12"Ø BOLTS AT 24" O.C. STAGGERED. HANGER JOISTS BY SUPPLIER. <br />13.PROVIDE 14" FULL DEPTH WEB STIFFENER PLATES OR END PLATES EACH SIDE OF WEB OVER ALL STEEL BEAM SUPPORTS, <br />DIRECTLY BELOW STACKED STEEL BEAMS, AND AT ENDS OF CANTILEVERS. STEEL COLUMN TOP AND BOTTOM PLATES <br />ARE BY THE MANUFACTURER (R = 40 KIPS UNLESS NOTED OTHERWISE). STEEL SHEAR CLIP CONNECTIONS (R = 20 KIPS <br />UNLESS NOTED OTHERWISE) ARE BY THE MANUFACTURER. <br />14.VERIFY DROPPED VERSUS FLUSH BEAM CONDITIONS WITH HOUSE PLANS. <br />15.ALL OTHER FASTENERS TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1). <br />16.ALL STUD PLIES IN BUILT UP COLUMNS AND AT INTERMEDIATE STUD FRAMING TO BE FASTENED TO SHEATHING / GYP <br />BOARD AS NOTED ABOVE (12" O.C. MAX. AT EXTERIOR AND 16" O.C. MAX. AT INTERIOR). <br />17.CUT PSL POSTS TO FIT EXCEPT AT STRUCTURAL BRACKETS. DO NOT BLOCK WITH WOOD PLATE MATERIAL, CRUSHING <br />WOULD OCCUR. FASTEN STEEL BEAMS TO ALL POSTS / STUDS w/ (4) 14"Ø x 5" SIMPSON SDS OR EQUIVALENT STRUCTURAL <br />WOOD SCREWS. WHERE TWO BEAMS BEAR AT ONE POST, TWO SCREWS PER BEAM ARE REQUIRED. AT BOTTOM, PSL TO <br />BEAR DIRECTLY ON CONCRETE OR SOLIDLY GROUTED POST BASE. IF UNTREATED, WRAP BOTTOM w/ MEMBRANE. <br />18.A BRACED WALL REVIEW HAS BEEN PERFORMED. DUE TO FULL ENGINEERING PROVIDED, EXTERIOR BRACED WALLS ARE <br />NOT SHOWN FOR CLARITY, BUT ARE COVERED BY CONTINUOUS SHEATHING AND CONNECTIONS NOTED ABOVE. <br />INTERIOR BRACED WALL ELEMENTS AND CONNECTIONS ARE SHOWN IN THESE DRAWINGS AS REQUIRED, AS WELL AS <br />ENGINEERED WIND RESISTING ELEMENTS THAT DO NOT MEET PRESCRIPTIVE CODE REQUIREMENTS. <br />19.IT IS THE OPINION OF THE HANSON GROUP THAT THE FRONT PORCH AND SCREEN PORCH ARE PRIMARILY OPEN, <br />NON-ESSENTIAL STRUCTURES AND ARE EXCLUDED FROM THE OVERALL MAIN WINDFORCE RESISTING SYSTEM OF THE <br />HOME. PROVIDE CODE REQUIRED UPLIFT CONNECTIONS AT POSTS. <br />20.TALL WALLS ARE DESIGNED FOR H/180 DEFLECTION CRITERIA (SIDING). CONTACT THE HANSON GROUP IF ADDITIONAL <br />STIFFNESS IS REQUIRED. <br />21.TRUSS SUPPLIERS DESIGNING ELEMENTS TO SUPPORT CONCRETE OR STONE VENEER ARE TO USE 1.5 X DEAD LOAD <br />PLUS LIVE LOAD AND L/600 DEFLECTION CRITERIA TO RESIST LONG TERM CREEP AND FINISHED MATERIAL DISTRESS. <br />SIMILAR DESIGN REQUIREMENTS PERTAIN TO TRUSSES SUPPORTING HEARTH / MANTLE STONE. <br />MATERIALS <br />CONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS (OR 3,500 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A <br />WATER AND VAPOR RESISTANCE AT LEAST EQUIVALENT TO 5,000 PSI CONCRETE) <br />CONCRETE WALLS: F'c = 3,500 PSI @ 28 DAYS <br />REINFORCING STEEL: ASTM A615 GRADE 60 <br />STRUCTURAL STEEL:ANGLES/MISC - ASTM A36 (Fy = 36KSI) <br />TUBES - ASTM A500 Gr. B (Fy = 46 KSI) <br />W SECTIONS - ASTM A992 (Fy = 50 KSI) <br />AGGREGATE: FOOTINGS - 112" MAX <br /> WALLS/SLABS - 3 4" MAX <br />ON-SITE SOIL:SANDY-CLAY (GROUP II) ASSUMED <br />geq = 45 PSF/FT (ACTIVE) <br />IF CLAY SOILS ARE ENCOUNTERED, BACKFILL w/ SAND FULL HEIGHT <br />BACKFILL SOIL:SAND (GROUP I) <br />TO BE USED WHERE NOTED: <br />geq = 30 PSF/FT (ACTIVE) <br />WALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTER <br />WALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTER <br />DIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTER <br />TREATED LUMBER:SYP NO.2 GRADE OR BETTER <br />TREATED GLULAM:SYP 26FV4 <br />LVL:13 4" WIDTH - Fb = 2600 PSI, E = 1,900,000 PSI <br />LVL (2x6 ALT):112" WIDTH - 2.0E OR BETTER <br />PSL:Fb = 2400 PSI, Fc = 2500 PSI, E = 1,800,000 PSI <br />LSL STUDS:Fb = 1700 PSI, E = 1,300,000 PSI <br />LSL STUDS (2x8):112" WIDTH - E = 1,500,000 PSI <br />ALLOWABLE SOIL <br />BEARING PRESSURE: 2,000 PSF (ASSUMED) <br />Project Number: <br />Date:S11Sheets: of <br />DescriptionDateRevision <br />5851 Cedar Lake Road <br />Suite 202 <br />St. Louis Park, MN 55416 <br />Tel 612-708-3572 <br />www.hansongroupmn.com <br />Print Name: <br />Signed: <br />License Number: <br />Trevor Axner <br />45470Date: <br />I hereby certify that this plan, specification or report <br />was prepared by me or under my direct supervision <br />and that I am a duly Licensed Professional Engineer <br />under the laws of the State of Minnesota. <br />COPYRIGHT HANSON GROUP, LLC 2024© <br />Eskuche Design Group <br />18318 Minnetonka Blvd <br />Deephaven, MN 55391 <br />2 <br />August 28, 2024 <br />4.128 <br />PLANS SHOWN LIGHT IN BACKGROUND ARE FOR <br />LOCATION REFERENCE ONLY. PLAN NOTES AND <br />ELEMENTS SHOWN LIGHT MAY NOT NECESSARILY <br />SUPPORT THE HANSON GROUP'S DESIGN. <br />BUILDER IS REQUIRED TO SEND FINAL TRUSS <br />LAYOUT DRAWINGS TO THE HANSON GROUP <br />PRIOR TO CONSTRUCTION FOR VERIFICATION OF <br />LOAD PATHS AND FRAMING SIZES LISTED <br />797 Ferndale Residence <br />797 Ferndale Rd N <br />Orono, MN <br />10-29-24 <br />ABBREVIATIONS <br />TYP.=TYPICAL <br />SIM.=SIMILAR <br />U.N.O.= UNLESS NOTED OTHERWISE <br />O.C.= ON CENTER <br />= CONTINUOUS OVER <br />CODES <br />2020 MINNESOTA RESIDENTIAL CODE <br />LOADS <br />ROOF LIVE LOAD: 35 PSF (SNOW) <br />ROOF DEAD LOAD:20 PSF <br />FLOOR LIVE LOAD:40 PSF <br />FLOOR DEAD LOAD:15 PSF <br />FLOOR DEAD LOAD:25 PSF AT TILE <br />THIN STONE LOAD :25 PSF (2" MAX.) <br />WIND LOAD:115 MPH ULTIMATE EXP. B 3'-6" MAX.VERIFY EXACTDIMENSIONS w/HOUSE PLANS6" <br />MIN. <br />SLOPE GRADE AWAY <br />FROM FOUNDATION <br />SLAB-ON-GRADE <br />#4 HORIZ. BAR <br />@ 24" O.C. <br />8" MIN. C.I.P. <br />CONCRETE WALL <br />12"Ø x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. <br /> WALL SECTION 7 <br />S1 LOOKOUT FOUNDATION WALL <br />INSULATION BY OTHERS <br />SEE HOUSE PLANS <br />20" MIN. WIDE x 8" MIN. <br />THICK CONCRETE FOOTING <br />CENTERED UNDER WALL - <br />LOWER AS REQ'D FOR <br />FROST PROTECTION <br />2x8 MIN. TREATED SILL <br />PLATE w/ 112" MAX. <br />OVERHANG <br />#4 x 2'-0" DOWELS (5" MIN. <br />EMBED) CENTERED IN <br />WALL @ 24" O.C. DOWELS <br />MUST BE WET SET OR <br />DRILLED AND EPOXY <br />GROUTED <br /> WALL SECTION 8 <br />S1 RETAINING WALL TYPE <br />STAIRWELL FOUNDATION WALL 11'-0"±VERIFY EXACT DIMENSIONS w/ HOUSE PLANS#4 HORIZ. BARS <br />@ 24" O.C. <br />VERTICAL BAR OPTIONS: <br />#5 BARS @ 24" O.C. <br />OR #6 BARS @ 36" O.C. <br />#4 BARS @ END, MIDDLE, <br />& BEND OF HOOK <br />6'-4" HOOK OPTIONS: <br />#5 HOOKS @ 12" O.C. OR <br />#6 HOOKS @ 18" O.C. <br />10" MIN. THICK C.I.P. <br />CONCRETE FOOTING4'-0"2" TO VERTICAL <br />BARS & HOOKS <br />4'-0"3"SLAB-ON-GRADE <br />LINE OF GRANULAR <br />BACKFILL <br />REQUIREMENTS <br />100% GRANULAR <br />OR GRAVEL <br />BACKFILL <br />w/ 6" CLAY <br />CAP <br />2'-0"1 <br />2 2'-4" <br />FRAME WALL <br />10" MIN. C.I.P. CONCRETE WALL <br />6" MIN. WIDTH x 12" MAX. HEIGHT C.I.P. <br />CONCRETE STEM WALLSLAB LEDGE <br />12"Ø ANCHOR BOLTS <br />(7" MIN EMBED) @ 72" O.C. MAX. - <br />CENTER IN STEM TREATED 2x8 SILL PLATE w/ 112" <br />MAX. OVERHANG <br />(1) #4 HORIZ. BAR @ TOP AND <br />BOTTOM OF STEM DOWELS <br />SLAB-ON-GRADE 11'-0"± TYP.REDUCE WALL HEIGHTS 112" AT DROPPED TOP CHORD LOCATIONSVERIFY EXACT DIMENSIONS w/ HOUSE PLANS20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />#4 HORIZ. BARS @ 24" O.C. <br />VERTICAL BAR OPTIONS: <br />#5 BARS @ 18" O.C. OR <br />#6 BARS @ 24" O.C. <br />10" MIN. C.I.P. <br />CONCRETE WALL <br />2" <br /> WALL SECTION 2 <br />S1 TYPICAL HOUSE FOUNDATION <br />WALLS w/ TOP CHORD BEARING <br />TRUSSES <br />SIMPSON A35 CLIP BOTH SIDES <br />OF TRUSS w/ (6) 8dx112" NAILS <br />EACH LEG OF EACH CLIP <br />2x8 MIN. SILL PLATE <br />w/ 112" MAX. OVERHANG <br />INSULATION BY OTHERS <br />SEE HOUSE PLANS <br />TOP-CHORD BEARING <br />TRUSSES BY SUPPLIER <br />@ 19.2" O.C. MAX. <br />(2) 2x8 BLOCKING <br />BETWEEN TRUSSES VERIFY IF TRUSSES <br />REQUIRE WIDER SILL <br />PLATE FOR BRG <br />CLOSER TO WEB <br />12"Ø ANCHOR BOLT (7" MIN. EMBED) w/ <br />NUT & 18" THICK x 2"Ø OR SQUARE <br />WASHER @ 24" O.C. (23 4" FROM EDGES <br />OF SILL / CONCRETE WALL) <br />#4 x 2'-0" DOWELS @ 72" O.C. <br />(5" MIN. EMBED) - IF SLAB IS NOTCHED <br />AT 112" DROPPED LOCATIONS NOTED <br />ON HOUSE PLANS, INCREASE DOWELS <br />TO 12" O.C. SPACING <br />SEE 3/S1 FOR TOP OF WALL CONNECTIONS <br />AT FLOOR NON-BEARING WALL <br />(2) 2x4 BLOCKING LAID <br />FLAT IN FIRST TRUSS <br />SPACE & 2x4 BLOCKING <br />LAID FLAT IN SECOND <br />TRUSS SPACE - <br />TOENAIL EACH END <br />FOR STABILITY <br />TRUSSES BY SUPPLIER <br />2x8 MIN. TREATED SILL PLATE <br />w/ 112" MAX. OVERHANG <br />(12) 0.131"Ø x 3" NAILS <br />THRU SHEATHING TO BLOCKING <br />FOUNDATION WALL <br />SEE 2/S1 <br />12"Ø ANCHOR BOLT (7" MIN <br />EMBED) w/ NUT & 18" THICK x <br />2"Ø OR SQUARE WASHER @ <br />24" O.C. (23 4" FROM EDGES <br />OF SILL / CONCRETE WALL) <br /> (2) 2x8 BLOCKING BETWEEN <br />PERPENDICULAR BLOCKING <br /> WALL SECTION <br />TYPICAL TOP OF WALL <br />PARALLEL TO FRAMING <br />TOP-CHORD BRG HEIGHT <br />SIMPSON A35 CLIP BOTH SIDES OF <br />BLOCKING w/ (6) 8dx112" NAILS EACH <br />LEG OF EACH CLIP <br />SPACE <br />BLOCKING <br />@ 24" O.C.3 <br />S1 <br />MAINTAIN 6" MIN. STEM <br />AT LEDGES <br />LEDGE AS REQ'D - VERIFY <br />LOCATIONS w/ HOUSE PLANS <br />SLAB-ON-GRADE <br />#4 x 2'-0" DOWELS @ 72" O.C. <br />(5" MIN. EMBED) <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />CENTERED UNDER WALL - <br />LOWER AS REQ'D FOR <br />FROST PROTECTION <br />SLAB-ON-GRADE <br />6" MIN. <br />#4 HORIZ. BAR <br />AT TOP OF WALL <br />6" MIN. STEM - SEE HOUSE <br />PLANS FOR HEIGHT <br />SLOPE GRADE <br />AWAY FROM <br />FOUNDATION <br />12"Ø x 10" LONG <br />ANCHOR BOLTS <br />(7" MIN. EMBED) <br />@ 72" O.C. MAX. <br />2x6 TREATED SILL PLATE <br />w/ NO OVERHANG <br />8" MIN. C.I.P. CONCRETE WALL <br />2" MIN. SLAB LEDGE <br /> WALL SECTION 6 <br />S1 FROST DEPTH FOUNDATION <br />WALL - GARAGE <br />7 <br />S1 <br />TYP. <br />LOOKOUT <br />2S1TYP.HOUSETC BRGSLAB-ON-GRADE 9'-3"±VERIFY EXACT DIMENSIONS w/ HOUSE PLANS#4 x 2'-0" DOWELS @ 72" O.C. <br />(5" MIN. EMBED) <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING - <br />LOWER FOOTING FOR FROST <br />PROTECTION AS REQ'D <br />#4 HORIZ. BARS @ 24" O.C.VERTICAL BAR OPTIONS: <br />#5 BARS @ 24" O.C. OR <br />#6 BARS @ 36" O.C. <br />8" MIN. C.I.P. CONCRETE WALL <br />2" <br /> WALL SECTION 4 <br />S1 TYPICAL HOUSE FOUNDATION <br />WALLS w/ BOTTOM CHORD <br />BEARING TRUSSES <br />6" <br />MIN. <br />FLOOR TRUSSES BY <br />SUPPLIER @ 19.2" O.C. MAX. <br />(TO BE DESIGNED FOR <br />PLATE OVERHANG) <br />SIMPSON A35 FRAMING ANGLE <br />EITHER SIDE OF TRUSS w/ (6) 8d x <br />112" NAILS EACH LEG OF EACH <br />ANGLE AND (3) 0.131" x 3" TOENAILS <br />SLOPE GRADE AWAY <br />FROM FOUNDATION <br />2x8 MIN. TREATED SILL PLATE <br />w/ 112" MAX. OVERHANG <br />12"Ø ANCHOR BOLT (7" MIN. EMBED) <br />w/ NUT & 18" THICK x 2"Ø OR SQUARE <br />WASHER @ 36" O.C. (23 4" FROM <br />EDGES OF SILL / CONCRETE WALL) <br />INSULATION BY OTHERS <br />SEE HOUSE PLANS <br />POSTS TO HAVE 112" MAX. OVERHANG TYP. - <br />WIDEN WALLS AS REQ'D - VERIFY BOLT <br />CLEARANCE REQUIRED FOR SELECTED <br />POST BASE - DO NOT PLACE FROST <br />SUSCEPTIBLE SOIL BELOW OVERHUNG EDGE <br />F1 4S1TYP.HOUSEBC BRGTHIS WALLONLY3 <br />S1TYP. <br />HOUSE <br />TC NON-BRG <br />6S1TYP.FROST5 <br />S1 <br />TALL LOOKOUT <br />2'-0"2'-0"THICKEN SLAB TO 5", REINFORCE w/ #3 BARS <br />@ 24" O.C. EACH WAY & PROVIDE #4 x 4'-0" <br />HOOKS SHOWN @ 24" O.C. IN FOUNDATION <br />WALLS AROUND PERIMETER AS APPLICABLE <br />AND CAST INTO INDICATED PORTION OF SLAB <br />6 <br />S2 <br />TYP. <br />LOW GRADE <br />Plan Updates10-29-241 <br />5'-6" MAX.VERIFY EXACTDIMENSIONS w/HOUSE PLANS6" <br />MIN. <br />SLOPE GRADE AWAY <br />FROM FOUNDATION <br />SLAB-ON-GRADE <br />#4 HORIZ. BAR <br />@ 24" O.C. <br />8" MIN. C.I.P. <br />CONCRETE WALL <br />12"Ø x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. - 48" O.C. <br />AT TALL STAIR WALLS <br /> WALL SECTION 5 <br />S1 TALL LOOKOUT FOUNDATION WALL <br />INSULATION BY OTHERS <br />SEE HOUSE PLANS <br />24" MIN. WIDE x 8" MIN. <br />THICK CONCRETE FOOTING <br />CENTERED UNDER WALL - <br />LOWER AS REQ'D FOR <br />FROST PROTECTION <br />2x8 MIN. TREATED SILL <br />PLATE w/ 112" MAX. <br />OVERHANG <br />#4 x 4'-0" HOOKED <br />DOWELS (5" MIN. <br />EMBED) CENTERED <br />IN WALL @ 18" O.C. <br />F1 F1 <br />RELATIVELY LEVEL <br />GRADE w/ GARAGE <br />SLAB AT THIS <br />CORNER - VERIFY <br />10'-0"± <br />SLAB-ON-GRADE <br />- SEE 1/S1 FOR <br />ADDITIONAL <br />SLAB / HOOK <br />REQUIREMENTS <br />NOT SHOWN <br />FOR CLARITY8S1TYP.STAIRF2F2 <br />3'-6"0'-6"