Laserfiche WebLink
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />OWNER --- <br />011 the .Vorflp Sbore' of <br />lake• .1linnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473.7357 <br />ADDRESS L1��` <br />PERMITNO.'S. .-10217 — DATES 12.51- VP --- CONTRACTORS 1­�P—sT0KA'—A 0-9y. <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage <br />treatment system at the above address has been inspected and appears co fall into the category checked below. <br />(This is X an existing system U new construction) <br />® 1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />2 Does not meet all current City standards fo: new construction (1978 Code) but in most respects appears to be designee+ <br />located, and constructed generally in accordance with previous cod,rs. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />a3 Does not meet current City standards tit many respecs relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high Potential for future problems. No major upgrading of system is required at <br />this time. <br />El4 System may or may not meet current City standards Ion design, construction or location, but is failing to Properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwateFs, or is <br />creating a safety harard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted log review- Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( [0 Checked items may require your action) <br />Tank inspection indicates <br />APumpout not needed at :his time. <br />❑ Solids accumulation in tanks indicates they should be pump - <br />ad out this year to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge, <br />❑ Inspection risers missing —tanks could not be inspected. <br />Ir..oection risers (4" dia. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />St. . CHARACTERISTICS <br />Limiting Site Factors <br />❑ Slope <br />r' - uil <br />❑ High water table <br />U Lui ;ire <br />,-Lake, wetland, or stream <br />❑ Drainage <br />COMMENTS <br />r i Inspection pipe is locate cl directly over tank baffle. (Does not <br />nive accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspectior indicates. <br />Drainfield is dry, no surfacing evident <br />❑ Some ev dance of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions to dramfield. Contact the City Inspector <br />immediately. Repairs must be cocipleted within 90 days, <br />❑ Drainfield extent and condition unknown. <br />Potential for System Failure <br />Idepends on soil types, water <br />tahe, risystr!m condition) <br />Lowd <br />L] Medium <br />L) High <br />System is causuig visible <br />sur fare discharge <br />Site Capabilities for <br />Fut re Expansion <br />Adequate <br />(� Fair <br />Cl Poor <br />7 Inadequate <br />Date of Inspection Ptic System Inspector <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property. be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the available information <br />This report must be kept on the premises with system location and pumiring records <br />WHIT, COPY - Insp><'clor's f .I,- GOt D COPY , Homeowner <br />