My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1978-09-14 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Farview Lane
>
2935 Farview Lane - 04-117-23-34-0009
>
Septic
>
1978-09-14 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2025 11:33:22 AM
Creation date
12/11/2025 11:26:44 AM
Metadata
Fields
Template:
x Address Old
House Number
2935
Street Name
Fairview
Street Type
Lane
Address
2935 Fairview Lane
PIN
0411723340009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 2. DESIGN <br />All tanks, regardless of material or method of construction, shall <br />conform to the following design criteria: <br />A. The LIQUID DEPTH of any septic tank of compartment thereof <br />shall be not less than 30 inches. A liquid depth greater <br />than six and one-half feet shall not be considered in de- <br />termining tank capacity. <br />B. No tank or compartment thereof shall have an inside horizontal <br />dimension less than 24 inches. <br />C. Inlet and outlet connect -ions of the tank thereof shall be sub- <br />merged by means of ven ., sanitary tees or baffled. <br />D. The space in the tank between the liquid surface and the top <br />of the inlet and outlet baffles or sanitary tees shall be not <br />less than 20 percent of the total required liquid capacity, <br />except that in horizontal cylindrical tanks this space shall <br />be not less than 15 percent of the total required liquid <br />capacity. <br />E. The inlet baffle or sanitary tee shall extend at least six <br />inches but not more than 20 percent of the total liquid depth <br />• below the liquid surface and at least one inch above the crown <br />of the inlet sewer, <br />F. The outlet baffle or sanitary tee and the baffles or sanitary <br />tees between compartments shall extend below the liquid surface <br />a distance equal to 40 percent of the liquid depth except that <br />the penetration of the indicated baffles or sanitary tees for <br />horizontal cylndrical tanks shall be 35 percent of the total <br />liquid depth. They also shall extend above the liquid surface <br />as required in D. above. In no case shall they extend less <br />than six inches above the liquid surface. <br />G. There shall be at least one inch between the underside of the <br />top of the tank and the highest point of the inlet and outlet <br />devices. <br />H. The inlet invert shall be not less than three inches above the <br />outlet invert. <br />I. The inlet and outlet shall be located opposite each other along <br />the axis of maximum'dimension. The horizontal distance between <br />the nearest points'of the inlet and outlet deices shall be at <br />least four feet. <br />0 <br />