1978-09-14 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Farview Lane
>
2935 Farview Lane - 04-117-23-34-0009
>
Septic
>
1978-09-14 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2025 11:33:22 AM
Creation date
12/11/2025 11:26:44 AM
Metadata
Fields
Template:
x Address Old
House Number
2935
Street Name
Fairview
Street Type
Lane
Address
2935 Fairview Lane
PIN
0411723340009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r • <br />*WOO* <br />545 Indian Mound <br />Wayzata, Minnesota 55391 <br />September 14, 1978 (612) 473-4224 <br />Mr. David Nitz <br />David Nitz, Inc. <br />491 West Ferndale Road <br />Wayzata, Minnesota 55391 <br />Re: Percolation Test and Systems Design for a Building Permit, <br />Lot 9, Block 1, Fairview Addition, Orono, Minnesota <br />Job Number 11-78-49 <br />Dear Mr. Nitz: <br />Enclosed is information requested in regards to the septic field suit- <br />e ability of Lot 9, Block 1, Fairview Addition. <br />The drainfield information is based on percolation tests and soil bor- <br />ings performed on September 7 and 8, 1978. <br />The soil found on the site is Lester loam. The soil is mapped in <br />Figure 1. The percolation rate for the primary field as tested was <br />• 27.5 Min./inch. The percolation rate for the secondary field as <br />tested was 23.3 Min./inch. The locations of the percolation test holes, <br />soil borings, and the proposed drainfield areas are indicated in <br />Figure 1. Percolation rates and depths to the water table are shown in <br />Table 1. The soil logs of the soil borings are shown in Table 2. <br />Because of the acceptable percolation rate and because of the acceptable <br />depth to the water table, a conventional on -site treatment system is <br />recommended for the areas shown in Figure 1. I have enclosed plans and <br />specifications for such a system. Additional copies of the plans and <br />specifications are available upon request. <br />Stated percolation rates are averaged for the locations shown, and no <br />guarantee is implied or exrressed that these conditions exist for the <br />entire test area. <br />If you have any questions, please do not hesitate to contact me. <br />Sincerely, <br />EUGENE A. HICKOK AND ASSOCIATES <br />James P. DeBenedet, P.E. <br />S JPD/jel <br />Enclosures <br />