My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1979-05-08 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Farview Lane
>
2820 Farview Lane - 04-117-23-34-0005
>
Septic
>
1979-05-08 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2025 8:34:34 AM
Creation date
12/11/2025 8:30:09 AM
Metadata
Fields
Template:
x Address Old
House Number
2820
Street Name
Fairview
Street Type
Lane
Address
2820 Fairview Lane
PIN
0411723340005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• D. Metal Tom. ,ks <br />Metal tanks shall have a wall thickness of at least eight gauge <br />corrosion resistant alloys and shall be coated inside and out <br />with at least one coat of bitumastic seal, Koppers 300-M, or by <br />other equivalent means. Tanks shall be carefully installed so as <br />not to puncture or damage the seal coating. <br />E. Block or Sectional Tanks <br />(1) Rectangular Blocks <br />V <br />(a) Rectangu-ar blocks shall be laid on an approved bottom. <br />Block shall be at least eight inches thick, constructed <br />of a 4,000 psi core test concrete mix, and cured to a <br />28-day strength before installation. <br />(b) Rectangular blocks shall be laid either with mortar <br />join:z or filled cores. <br />' (c) There ahall be at least two coats of 1/4 inch thick <br />concrete plaster placed on the inside of the block tank. <br />There shall be at least two hours elapsed time between <br />coats. The plaster coat shall start at the bottom course <br />and work up. <br />(2) Circular Block Tanks <br />(a) Circular blocks shall be carefully placed on an approved <br />bottom. Circular blocks shall be at least two inches <br />thick and constructed of a 4,000 psi core test concrete <br />mix, cured to a 28-day strength before installation. <br />(b) There shall be at least two coats of 1/4 inch thick <br />concrete plaster placed on the Inside of the block tank. <br />There shall be at IL-ast two hours elapsed time between <br />coats. The plaster coat shall start at the bottom course <br />and work up. <br />(3) Sectional Tanks <br />(a) A sectional tank shall have an entire section cast as an <br />integral unit. <br />(b) A sectional tank shall have two or more sections and shall <br />have at least one joint below the level of the outlet in- <br />vert of the tank. <br />(c) Sectional tanks shall have an integLally cast bottom, or <br />shall be laid on an approved bottom. <br />:7 <br />-2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.