Laserfiche WebLink
CITY of ORONO <br />Munkipai Memo; <br />SAM Was& <br />•, �uNr iwws+s: <br />2750 Kelley Parkway P.O. Box 66 <br />Orono, MN 55356 Crystal Bay, MN 55323.00% <br />Owner: V"d TO& Address: 2611 tarviow Ln. <br />--sr <br />Permit V a: 9132 Dates: 7/29/87 Contractors: Widmer Bros. <br />(This is (Jj an existing system E ] new construction). <br />ST. EM COh:- :A : _ - 1 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />3 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottom of <br />the drainfield and the saturated soil level. <br />(The saturated soil level is E ] or is not E ) identified under this septic system. If the <br />saturated soil level is not identified, this classification is subject to revision.) <br />TANK COND:TION (5-9): 9 <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed now. <br />0 Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pu_-7 ped out within three !ears, they should be pumped out now. <br />10 One or more tanks are cesspools, which means the septic system is non -compliant. <br />(The tanks are E ] or are not E ] water tight or the condition is ( ] unknown. If the tanks <br />are not confirmed to be watertight, this classification is subject to revision.) <br />DRAINFIELD CONDITION (11-14): 11 <br />47 Drainfield is dry, no surfacing evident. <br />12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br />the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): low <br />COMMENTS: In order to confi- iat your septic system meets Minnesota standards, soil borings <br />were performed to verify a 2 Varaticn between the drainfield and the sea__na l water tabl-. <br />The separation is 3 feet and .em is compliant. <br />S/-/-?q 4rLZ4__--' <br />Date of Inspection c Syst m nspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tekphone (612) 2494600 • Fax (612) 249-"16 <br />