1991-07-18 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
F
>
Farview Lane
>
2811 Farview Lane- 04-117-23-34-0003
>
Septic
>
1991-07-18 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2025 2:05:05 PM
Creation date
12/10/2025 1:55:40 PM
Metadata
Fields
Template:
x Address Old
House Number
2811
Street Name
Fairview
Street Type
Lane
Address
2811 Fairview Lane
PIN
0411723340003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the North Sh. om of' <br />lake ,Winntelonka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1,135 S. Brown Rd. <br />OPONO Lysol Bay, MN 55323 <br />473-7357 <br />OWNER ADDRESS <br />PERMIT NO.-S. -?' 'tea — DATES807 -- CONTRACTORS LZC K SM, <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono he inspected on a regular basis. The on -site sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below <br />(this is 5f an existing system n new construction) <br />JR1 Meets or exceeds current City standards in all respects relating to design, construction, and location Appears to he operating <br />properly. <br />ED2 Does not meet all current City standards for new construction (1978 Code) but inmost respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be. functioning properly, no major <br />upgrading of the system is required at this time. <br />3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />4 System may or may not meet current City standards foi design, construction of location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repairi <br />replacement procedures. If dramlreld replacement is necessary, sod testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION I m Checked items may require your action) <br />TankJ'nspection indicates. <br />;wPumpout not needed at this time. <br />❑ Solids accumulation in tanks indicates they should bepump- <br />ad out this year to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risers missing —tanks could not be inspected. <br />Inspection risers 14" dia. pipe) must be installed in each tank <br />at next pumpout. If tanks hove not been pumped out within <br />the lost three years, they should be pumped out now. <br />SITE CHARACTERISTICS <br />Limiting Site ' .ctors <br />❑ Slope <br />❑ Sod <br />High water table <br />❑ Lot size <br />❑ Lake, wetland, or stream <br />❑ Drainage <br />COMMENTS <br />11 Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Ora in field inspection indicates. <br />Drainfield is dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace. <br />ment or additions to drainfreld. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />(] Drainfield extent and condition unknown. <br />Potential for System Failure <br />(depends on sod types, water <br />table and system condition) <br />�ow <br />Ci Mednun <br />l_) Hign <br />System is causing visible <br />surface discharge <br />Date of Inspection ptic System Inspector <br />Site Capabilities for <br />Future Expansion <br />dequate <br />❑ Fan <br />(7 Poor <br />n Inadequate <br />Note In the event that this inspection re;�,)rt is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the available, information <br />This report must be kept on the premises with system ]oration and pumping records. <br />WHITE COPY i Inspector's File GOLD COPY , Homeowner <br />