Laserfiche WebLink
ISWG1048COC Rev D <br /> <br /> <br />CERTIFICATION OF COMPLIANCE <br />Contains: WG1048E, WG1048EBLK, WG1048EGR, or WG1048EDGR <br />Description: 8” Round Suction Outlet Cover <br />Ra tings : Floor: ______ 1 2 5 GPM ___ Wall: ______ 72 GP M __________ Open Area:__8.1 sq-in___ <br />Certified to Comply with Section 1404 of the Virginia Graeme Baker Act (VGB) Pool & Spa Safety Act <br />codified at 16 CFR part 1450. Initial Certification May 2011. <br />Manufactured: After September 10, 2009, by a Division of Hayward Industries, Inc. at K4-A, 214028 <br />Block K4- A, Export Processing Zone Wuxi New District Jiangsu Province PRC 214028, China; or at <br />One Hayward Industrial Drive, Clemmons, NC 27012. <br />Certified by Hayward Pool Products, 620 Division Street, Elizabeth, NJ 07207, Phone 908-355-7995 <br />Contact at www.haywardnet.com <br />Record Custodian is Customer Service at www.haywardnet.com. <br />Hayward Pool Products P.O. Box 5100 Clemmons, NC 27012-5100, Phone: 336-712-9900 <br />http://www.hayward-pool.com/pdf/literature/8inroundCOC.pdf <br />Date of Mfr: The Lot Number shown on the product label contains the Year & Month of manufacture. <br />The first number represents the year (ex 1 = 2011) and the second character the month (A=Jan, <br />B=Feb, H=Aug, I is skipped, J=Sep, etc) <br />Tested to: ANSI/APSP 16 (ANSI/ASME 112.19.8-2007 (addendum 9b-2009)) per Section 1404 of the <br />Virginia Graeme Baker Act (VGB) Pool & Spa Safety Act. Tested by NSF International, 789 Dixboro <br />Road, Ann Arbor, MI 48113, Phone 734-769-8010 in April 2011. Certificate at: <br />http://info.nsf.org/Certified/Pools/Listings.asp?Company=21600&Standard=ASME1908 <br />Date of Installation:______________________ <br />Suction outlet components have a finite life, the cover/grate should be inspected frequently and <br />replaced at least every 77 ye ars or if found to be damaged, broken, cracked, missing, or not securely <br />attached. <br />Hayward Pool Products acknowledges that it is a federal crime to knowingly and willingly make <br />materially false, fictitious, or fraudulent statements, representations, or omissions on this <br />certification. <br />Warning – Suction Entrapment Hazard. <br />Suction in suction outlets and/or suction outlet covers which are installed in a small area and/or below the surrounding <br />surface can cause severe injury or death due to body entrapment hazard. <br />To reduce the risk of body entrapment, installation of the field fabricated sumps must be such that the top of the <br />mounted cover is a minimum of 1 1/2” above the finished pool surface over an area larger than 40” on a diagonal.