My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11-24-2025 - Agenda Packet Cc - Regular Meeting
Orono
>
City Council
>
2025
>
11-24-2025 - Agenda Packet Cc - Regular Meeting
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2025 3:29:23 PM
Creation date
11/24/2025 3:12:08 PM
Metadata
Fields
Template:
Administration
Admin Doc Type
Agenda Packet CC
Section
City Council
Subject
Regular Meeting
Document Date
11/24/2025
Retention
After
Protection
Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
468
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
968.10 <br />N164485.9�CURB STOP <br />L - <br />/ E442721.0 <br />soFOX SIREET <br />W <br />/ <br />FMo� <br />1 NOPE <br />LEGEND <br />DESCRIPTION <br />PROPOSED <br />EXISTING <br />BUILDING SETBACK LINE <br />BSBL <br />GARAGE SETBACK LINE <br />PARCEL BOUNDARY LINE <br />DRAINAGE AND UTILITY EASEMENTS <br />- <br />CURB AND GUTTER <br />RIGHT-OF-WAV <br />SANNIM SERVICE <br />�5 <br />�S- <br />BACKYARDCATCH BASIN <br />CATCH BASIN <br />STORM SEWERMANHOLE»- <br />FIAREDENDSECTIONWIRIP-RAP <br />STORM STUCTURE LABEL <br />CB H3 <br />CB H3 <br />DRAINTILE W EANOUTS <br />- - - - <br />- - - - -0 <br />SANITARY STUCTURE LABEL <br />SANITARY SEWER MANHOLE <br />WATERMAINI- <br />HYDRANT <br />- <br />GATE VALVE <br />O� <br />/ O�e� MIu.4 sBPBRAnou FORCBMau ro Gasuue 96715 967.45 -_ <br />� \ PVC FORCE MAIN VALVE <br />.8 N164485.3, <br />N 164482 <br />� o E442720.0 I E442721.3 <br />NOTES: <br />STATION 16+05 TO 17+10, FORCEMAIN TO BE INSTALLED 2' FROM EDGE OF RIGHT OF WAY (ROW) <br />NEAR / CROSSING GAS MAIN. GAS MAIN TO BE POTHOLED AS NEEDED FOR VERIFICATION. <br />NOTES: <br />\ STATION 22+00 TO 28+25, FORCEMAIN TO BE INSTALLED 2' FROM EDGE OF RIGHT OF WAY <br />(ROW) UNDER GAS MAIN. GAS MAIN TO BE POTHOLED AS NEEDED FOR VERIFICATION. <br />1010 <br />1010 <br />1000 <br />r r <br />1000 <br />EG <br />FUTURE AIR RELEHST \ <br />APPROX. EG VALVE LOCATION \ <br />CL FO%ST. i� <br />990 <br />/ <br />990 <br />MiDEPTH FM <br />T181.1 <br />FMHE\ <br />T-9886 <br />FM <br />2' SOR 11 HDPE FM <br />TA&8 ] <br />---- <br />7.5' DE <br />\ <br />980 <br />FM <br />980 <br />� T 9]B.B <br />FM <br />\ <br />� FM <br />970 <br />T-9]0.7 <br />G <br />7.5' DEPTH <br />T9688 FM <br />ACLFOXSG EG <br />970 <br />OX. EG <br />-OX ST FM <br />z <br />FM BEND <br />)]ham <br />----- - --------------------------------T-9854---,----- ---------------------------------------------------------------------------------------------- - <br />----------- ------------------------------------------------------------------------------------------------------ <br />- ----- ----- -- --- - <br />- ---.. ---- <br />TA698 <br />-------------- - <br />- -- -- -- -------------------- -.. <br />FM _ 458END58 <br />FLUSHING STA EXT. FM <br />TA58.3 T-958b 7.5' DEPTH <br />960 <br />FM <br />A58.2---• <br />FM -ISO VALVE <br />A59.4- <br />M-LP FM <br />960 <br />950 <br />950 <br />940 <br />940 <br />26+00 25+00 24+00 23+00 22+00 21+00 20+00 <br />19+00 <br />18+00 17+00 <br />16+00 <br />15+00 <br />50 2115-, 0 21�5--5110 1100 <br />EXISTING UTILITIES SHOWN ARE SHOWN IN AN APPROXIMATE WAV ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT <br />__L ElQ Q Q ■ <br />NQ <br />LOCATION OF ANY AND ALL EXISTING <br />AND ALL DAMAGES ARISING OUT OF <br />UTILITIES BEFORE COMMENCING <br />HIS FAILURE TO EXACTLY LOCATE <br />WORK. HEAGREESTOBEFULLVRESPONSIBLEFORANY <br />AND PRESERVE ANY AND ALL EXISTING UTILITIES. <br />Rj�` ALE IN FEET <br />DRAWING NAME <br />NO. <br />BY <br />DATE <br />REVISIONS <br />USE (INCLUDING COPYING, DISTRIBUTION, AND/OR CONVEYANCE OF <br />I HEREBY CERTIFY THAT THIS PLAN OR SPECIFICATION WAS <br />s"? <br />CITY PROJECT NO. <br />FILE NO. <br />XXX <br />1 <br />MJV <br />10/09/24 <br />CITY REVIEW COMMENTS- 10/02/24 <br />INFORMATION) OF THIS PRODUCT IS STRICTLY PROHIBITED WITHOUT <br />PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I <br />�EEas <br />--- <br />FORCE MAIN AS -BUILT PLAN <br />369IM01 <br />DRAWN BY <br />2 <br />DLS <br />11/07/2025 <br />AS-BUILTS <br />SATHRE-BERGQUIST, INC.'s EXPRESS WRITTEN AUTHORIZATION. USE WITHOUT <br />SAID AUTHORIZATION CONSTITUTES AN ILLEGITIMATE USE AND SHALL THEREBY <br />AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />W <br />o <br />SATHRE-BERGQUIST, INC. <br />MJV <br />INDEMNIFY SATHRE-BERGQUIST, INC. OF ALL RESPONSIBILITY. <br />/7 �]y <br />„„ <br />1400025TH AVE N#120 PLYMOUTH, MN. 55447 (952)47G6000 <br />ORONO, <br />LEAF & FOX STREET <br />CHECKED BY <br />SATHRE-BERGQUIST, INC. RESERVES THE RIGHT TO HOLD ANY ILLEGITIMATE <br />OR PARTY LEGALLY RESPONSIBLE FOR DAMAGES OR LOSSES RESULTING�MINNESOTA <br />,JI� ... I/ / ��(��i�/ <br />DANIEL L. SCHMIDT, P.E. <br />mDLSUSER <br />ANDERSON REDA <br />nd <br />DATE <br />FROM ILLEGITMATE USE. <br />09-20-2024 26147 <br />sP <br />ryP09-12-24 <br />Date: Lic. ND. <br />
The URL can be used to link to this page
Your browser does not support the video tag.