Laserfiche WebLink
But, where an existing drainfield is failing and needs to be replaced, <br />it is not generally feasible to tear up the existing drainfield and <br />re -use the same site unless the existing drainfield is taken out of <br />commission for a period of time and allowed to totally dry out. Then, <br />it is conceivable that the old trenches could be re -excavated to a <br />width and depth just greater than the old system, i.e. removing the <br />trench wall areas that have become reduced in absorption capacity due <br />to the biomat. <br />This would only be considered if the existing drainfield site is <br />the only possible site, and if soil and water conditions are suitable <br />for a drainfield system. As described in the system inventory, many <br />existing systems could not be'replaced within the confines of the <br />minimum code standards. <br />In general, Orono's policy has been to allow repairs to failing <br />systems by salvaging whatever components can be expected to continue <br />satisfactorily without jeopardizing the rest of the system, and <br />replacing system components that have outlived their usefulness or <br />would be detrimental to proper functioning if they remained as part of <br />the system. A typical septic system repair will include the addition <br />of drainfield using the existing tanks, often adding a 3rd pumping <br />tank when the drainfield needs to be located uphill. Tanks in poor <br />condition or located in high groundwater areas usually are replaced <br />with sealed, precast concrete tanks. Approximately 1/3 to 1/2 of all <br />repair jobs include a pump system or re-routing of plumbing in the <br />house in order to place drainfield on higher, dryer gound. In <br />gene•i1, drainfield additions, when proposed, are required to meet all <br />standards of the code for location in suitable soils and soil water <br />conditions, and are sized based on standards for new homes. In past <br />cases where these standards were not met, some replacement drainfields <br />failed to function from the day they were installed. <br />Given the lot area requirements, lot line and structural setback <br />requirements, soil permeability and water table depth criteria, the <br />mizcL of houses, the topography, locations and construction of exist- <br />ing systems and the locatiu,i �,f existing wells, the replacement of <br />existing septic systems in Crystal Bay with systems tnaL file6t the <br />minimum acceptable code standards is impossible on 26% of the proper- <br />ties and is severely limited or questionable on another 45%. Only 29% <br />of the properties have what could be considered as adequate area for <br />replacement and permanent usage of septic systems. <br />Note also that the continued use of septic systems will in many <br />cases effectively limit the opportunity for expansion of houses or for <br />adding garages where none exist and act as a severely limiting factor <br />in the upgrading of the Crystal Bay neighborhood. At least one bed- <br />room addition proposal is on hold pending resolution of the Crystal <br />Bay sewer situation. <br />Estimated costs for replacing septic systems in Crystal Bay vary <br />depending on the specific site, access to it, and capability for <br />replacement. In general current costs are as follows: <br />9 <br />