Laserfiche WebLink
264"6"11'-5 3/8"POURED CONC. FOUNDATION WALL W/REINFORCEMENT PER STRUCTURALCAPILLARY BREAKPOURED CONC. FOOTINGSIZE & REINFORCEMENT PER STRUCTURALVERIFY SOIL BEARING CAPACITYFOOTING TO REST ON UNDISTURBED SOILTOP OF FOOTING TO BE BELOW FROST LINESTEP FOOTING AS REQUIREDPERFERATED DRAIN TILE TO DAYLIGHT OR SUMPBACKFILL W/ ROCK OVER TILE AND UP WALL 24" MIN.COVER ROCK W/ FILTER MEMBRANEFOUNDATION PLAN DIMENSIONS ARETO FACE OF CONCRETEEL. 100'-0"T.O. SLAB AT LOWER LEVEL10"24A4.11SCALE: 1 1/2" = 1'-0"SECTION AT LOUNGE/ENTRY1'-10"TYPICAL FOUNDATION WALL ASSEMBLY·2" RIGID INSULATION ABOVE GRADE W/·PRE-FINISHED METAL SLIP SHEET - RUN 6" TO 8" BELOW GRADE·2 3/8" TREMCO WARM-N-DRI (R-10) BELOW GRADE·TREMCO TUFF-N-DRI SPRAYED FROM T.O. FTG. TO T.O. FOUNDATION·POURED CONC. FOUNDATION WALL - SEE STRUCTURAL FOR SIZE AND REINF.·1" FOIL FACE RIGID INSULATION (R-5) - TAPE ALL SEAMS·2x4 WOOD STUDS AT 16" O.C. - HOLD 1 1/2" OFF FACE OF FOUNDATIONWALL·1/2" GYP. BD.4" CONC. SLAB W/ WIRE MESH2" RIGID INSULATION OVER6 MIL POLY VAPOR RETARDER W/LAPPED AND TAPED JOINTS4" MIN. A.B.C.EXPANSION JOINT - SEALEDFLOOR FINISH PER SCHEDULE2x4 AT 16" O.C.1/2" GYP. BD.AIR SPACEBASE PER SCHEDULE1" RIGID INSULATION2424242 3/8" TREMCO WARM-N-DRI (R-10)264"6"POURED CONC. FOUNDATION WALL W/REINFORCEMENT PER STRUCTURALCAPILLARY BREAKPOURED CONC. FOOTINGSIZE & REINFORCEMENT PER STRUCTURALVERIFY SOIL BEARING CAPACITYFOOTING TO REST ON UNDISTURBED SOILTOP OF FOOTING TO BE BELOW FROST LINESTEP FOOTING AS REQUIREDPERFERATED DRAIN TILE TO DAYLIGHT OR SUMPBACKFILL W/ ROCK OVER TILE AND UP WALL 24" MIN.COVER ROCK W/ FILTER MEMBRANEFOUNDATION PLAN DIMENSIONS ARETO FACE OF CONCRETEEL. 100'-0"T.O. SLAB AT LOWER LEVEL10"11'-5 1/2"10"A4.12SCALE: 1 1/2" = 1'-0"SECTION AT GARAGE 2 & ART HALL1'-10"28TYPICAL FOUNDATION WALL ASSEMBLY·2" RIGID INSULATION ABOVE GRADE W/·PRE-FINISHED METAL SLIP SHEET - RUN 6" TO 8" BELOW GRADE·2 3/8" TREMCO WARM-N-DRI (R-10) BELOW GRADE·TREMCO TUFF-N-DRI SPRAYED FROM T.O. FTG. TO T.O. FOUNDATION·POURED CONC. FOUNDATION WALL - SEE STRUCTURAL FOR SIZE AND REINF.·1" FOIL FACE RIGID INSULATION (R-5) - TAPE ALL SEAMS·2x4 WOOD STUDS AT 16" O.C. - HOLD 1 1/2" OFF FACE OF FOUNDATIONWALL·1/2" GYP. BD.2 3/8" TREMCO WARM-N-DRI (R-10)4" CONC. SLAB W/ WIRE MESH2" RIGID INSULATION OVER6 MIL POLY VAPOR RETARDER W/LAPPED AND TAPED JOINTS4" MIN. A.B.C.EXPANSION JOINT - SEALEDFLOOR FINISH PER SCHEDULE2x4 AT 16" O.C.1/2" GYP. BD.AIR SPACEBASE PER SCHEDULE1" RIGID INSULATION24242426POURED CONC. FOUNDATION WALL W/REINFORCEMENT PER STRUCTURALCAPILLARY BREAKPOURED CONC. FOOTINGSIZE & REINFORCEMENT PER STRUCTURALVERIFY SOIL BEARING CAPACITYFOOTING TO REST ON UNDISTURBED SOILTOP OF FOOTING TO BE BELOW FROST LINESTEP FOOTING AS REQUIREDPERFERATED DRAIN TILE TO DAYLIGHT OR SUMPBACKFILL W/ ROCK OVER TILE AND UP WALL 24" MIN.COVER ROCK W/ FILTER MEMBRANEFOUNDATION PLAN DIMENSIONS ARETO FACE OF CONCRETE10 1/2"EL. 100'-0"T.O. SLAB AT LOWER LEVELEL. 110'-11 7/8"T.O. SUB FLR AT MAIN LEVEL4 1/2" <br />6 3/4"4"6"10"plywood extends over to tie2810"11'-4"242424A4.13SCALE: 1 1/2" = 1'-0"SECTION AT MASTER1'-10"TYPICAL FOUNDATION WALL ASSEMBLY·2" RIGID INSULATION ABOVE GRADE W/·PRE-FINISHED METAL SLIP SHEET - RUN 6" TO 8" BELOW GRADE·2 3/8" TREMCO WARM-N-DRI (R-10) BELOW GRADE·TREMCO TUFF-N-DRI SPRAYED FROM T.O. FTG. TO T.O. FOUNDATION·POURED CONC. FOUNDATION WALL - SEE STRUCTURAL FOR SIZE AND REINF.·1" FOIL FACE RIGID INSULATION (R-5) - TAPE ALL SEAMS·2x4 WOOD STUDS AT 16" O.C. - HOLD 1 1/2" OFF FACE OF FOUNDATIONWALL·1/2" GYP. BD.2 3/8" TREMCO WARM-N-DRI (R-10)4" CONC. SLAB W/ WIRE MESH2" RIGID INSULATION OVER6 MIL POLY VAPOR RETARDER W/LAPPED AND TAPED JOINTS4" MIN. A.B.C.EXPANSION JOINT - SEALEDFLOOR FINISH PER SCHEDULE2x4 AT 16" O.C.1/2" GYP. BD.AIR SPACEBASE PER SCHEDULE1" RIGID INSULATION242424A4.1DETAILSMASSOPUST RESIDENCE <br />1735 Fox St <br />Orono, MN 55391PROJECT NO: 229SHEET:© James McNeal Archecture & Design, LLC <br />THESE ARCHITECTURAL PLANS AND THE HOME <br />CONSTRUCTED PURSUANT TO THE PLANS ARE <br />THE EXCLUSIVE COPYRIGHTED PROPERTY OF <br />JAMES McNEAL ARCHITECTURE & DESIGN, <br />LLC AND ARE PROTECTED BY UNITED STATES <br />COPYRIGHT LAW. ANY UNAUTHORIZED USE <br />OF THESE PLANS IS STRICTLY PROHIBITED. <br />Copyright © 2022 <br />275 Market Street Suite 135 <br />Minneapolis, MN 55405 <br />877-796-JMAD <br />www.JamesMcNealArchitectureAndDesign.com ISSUE:08/22/22 - For Struct.09/09/2209/15/22 - Permit Set12/22/22 - For Struct12/28/22 - Permit Set15250 Wayzata Blvd.Wayzata, MN 55391952-404-7204www.hendelhomes.comSee Engineering