Laserfiche WebLink
CONCRETE LAP SPLICE LENGTH (IN INCHES) FOR CLASS B LAP SPLICES <br />(BASED ON ACI 318-11 SECTION 12.2/ACI 318-14 SECTION 25.4) <br />MODIFY THE LAP SPLICE LENGTHS AS REQUIRED BY NOTES BELOW <br />BAR LOCATION <br />TOP <br />OTHER <br />BAR SIZE CONCRETE STRENGTH <br />3000 PSI 4000 PSI <br />#3 <br />#4 <br />#5 <br />#7 <br />#8 <br />#11 <br />#10 <br />#9 <br />#6 <br />28 <br />38 <br />47 <br />56 <br />81 <br />93 <br />105 <br />118 <br />131 <br />25 <br />33 <br />41 <br />49 <br />71 <br />81 <br />91 <br />102 <br />114 <br />#3 <br />#4 <br />#5 <br />#7 <br />#8 <br />#11 <br />#10 <br />#9 <br />#6 <br />22 <br />29 <br />36 <br />43 <br />63 <br />72 <br />81 <br />91 <br />101 <br />19 <br />25 <br />31 <br />37 <br />54 <br />62 <br />70 <br />79 <br />87 <br />LAP SPLICE LENGTH NOTES: <br />1. TOP INDICATES HORIZONTAL BARS WITH MORE THAN 12 INCHES OF CONCRETE CAST BELOW BARS. <br />2. MUTIPLY THE LENGTHS IN THE SCHEDULE BY THE APPROPRIATE MODIFIERS WHEN REQUIRED: <br />1.3 FOR LIGHTWEIGHT CONCRETE <br />1.5 FOR BAR COVERS LESS THAN THE BAR DIAMETER <br />1.5 FOR BAR SPACING LESS THAN TWO BAR DIAMETERS <br />2023 Larson Engineering, Inc. All rights reserved. <br />Sheet Title: <br />Checked by: <br />Drawn by: <br />Project No: <br />No:Date:Description: <br />Date: <br />Revisions: <br />Sheet No: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION, OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED PROFESSIONAL ENGINEER <br />UNDER THE LAWS OF THE STATE OF <br />MINNESOTA. <br />PRINT NAME: BRANDON CLARK <br />SIGNATURE: <br />DATE: 08/21/2023 LIC. NO: 60507 <br />08/21/2023 <br />BC <br />DJC <br />11230536 <br />S0 <br />GENERAL STRUCTURAL <br />NOTES 2785 SHADYWOOD ROADORONO, MN 55331KOSKIE RESIDENCETABLE 602.3(1) <br />FASTENING SCHEDULE—continued <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; 1 ksi = 6.895 MPa. <br />(continued) <br />ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c SPACING AND LOCATION <br />Floor <br />24 2" subfloor to joist or girder 3-16d box (31/2" × 0.135"); or <br />2-16d common (31/2" × 0.162")Blind and face nail <br />25 2" planks (plank & beam—floor & roof)3-16d box (31/2" × 0.135"); or <br />2-16d common (31/2" × 0.162")At each bearing, face nail <br />26 Band or rim joist to joist <br />3-16d common (31/2" × 0.162") <br />4-10 box (3" × 0.128"), or <br />4-3" × 0.131" nails; or <br />4-3" × 14 ga. staples, 7/16" crown <br />End nail <br />27 Built-up girders and beams, 2-inch lumber <br />layers <br />20d common (4" × 0.192"); or Nail each layer as follows: 32" o.c. <br />at top and bottom and staggered. <br />10d box (3" × 0.128"); or <br />3" × 0.131" nails <br />24" o.c. face nail at top and bottom <br />staggered on opposite sides <br />And: <br />2-20d common (4" × 0.192"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />Face nail at ends and at each splice <br />28 Ledger strip supporting joists or rafters <br />4-16d box (31/2" × 0.135"); or <br />3-16d common (31/2" × 0.162"); or <br />4-10d box (3" × 0.128"); or <br />4-3" × 0.131" nails <br />At each joist or rafter, face nail <br />29 Bridging or blocking to joist <br />2-10d box (3" × 0.128"), or 2-8d common <br />(21/2" × 0.131"; or 2-3" × 0.131") nails Each end, toe nail <br />ITEM DESCRIPTION <br />OF BUILDING ELEMENTS <br />NUMBER AND <br />TYPE OF FASTENERa, b, c <br />SPACING OF FASTENERS <br />Edges <br />(inches)h <br />Intermediate <br /> supportsc, e <br />(inches) <br />Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing <br />[see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] <br />30 3/8" – 1/2" <br />6d common (2" × 0.113") nail (subfloor, wall)i <br />8d common (21/2" × 0.131") nail (roof); or <br />RSRS-01 (23/8" × 0.113") nail (roof)j <br />612f <br />31 19/32" – 1"8d common nail (21/2" × 0.131"); or RSRS-01; <br />(23/8" × 0.113") nail (roof)j 612f <br />32 1 <br />1/8" – 11/4"10d common (3" × 0.148") nail; or <br />8d (21/2" × 0.131") deformed nail 612 <br />Other wall sheathingg <br />33 1/2" structural cellulosic fiberboard <br />sheathing <br />11/2" galvanized roofing nail, 7/16" head <br />diameter, or 11/4" long 16 ga. staple with 7/16" or <br />1" crown <br />36 <br />34 25/32" structural cellulosic <br />fiberboard sheathing <br />13/4" galvanized roofing nail, 7/16" head diameter, <br />or 11/2" long 16 ga. staple with 7/16" or 1" crown 36 <br />35 1/2" gypsum sheathingd 11/2" galvanized roofing nail; staple galvanized, <br />11/2" long; 11/4" screws, Type W or S 77 <br />36 5/8" gypsum sheathingd 13/4" galvanized roofing nail; staple galvanized, <br />15/8" long; 15/8" screws, Type W or S 77 <br />Wood structural panels, combination subfloor underlayment to framing <br />37 3/4" and less 6d deformed (2" × 0.120") nail; or <br />8d common (21/2" × 0.131") nail 612 <br />38 7/8" – 1"8d common (21/2" × 0.131") nail; or <br />8d deformed (21/2" × 0.120") nail 612 <br />39 1 <br />1/8" – 11/4"10d common (3" × 0.148" ) nail; or <br />8d deformed (21/2" × 0.120") nail 612TABLE R602.3(1)—continued <br />FASTENING SCHEDULE <br />(continued) <br />ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c SPACING AND LOCATION <br />14 Bottom plate to joist, rim joist, band joist or <br />blocking (not at braced wall panels) <br />16d common (31/2" × 0.162")16" o.c. face nail <br />16d box (31/2" × 0.135"); or <br />3" × 0.131" nails 12" o.c. face nail <br />15 Bottom plate to joist, rim joist, band joist or <br />blocking (at braced wall panel) <br />3-16d box (31/2" × 0.135"); or <br />2-16d common (31/2" × 0.162"); or <br />4-3" × 0.131" nails <br />3 each 16" o.c. face nail <br />2 each 16" o.c. face nail <br />4 each 16" o.c. face nail <br />16 Top or bottom plate to stud <br />4-8d box (21/2" × 0.113"); or <br />3-16d box (31/2" × 0.135"); or <br />4-8d common (21/2" × 0.131"); or <br />4-10d box (3" × 0.128"); or <br />4-3" × 0.131" nails <br />Toe nail <br />3-16d box (31/2" × 0.135"); or <br />2-16d common (31/2" × 0.162"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />End nail <br />17 Top plates, laps at corners and intersections <br />3-10d box (3" × 0.128"); or <br />2-16d common (31/2" × 0.162"); or <br />3-3" × 0.131" nails <br />Face nail <br />18 1" brace to each stud and plate <br />3-8d box (21/2" × 0.113"); or <br />2-8d common (21/2" × 0.131"); or <br />2-10d box (3" × 0.128"); or <br />2 staples 13/4" <br />Face nail <br />19 1" × 6" sheathing to each bearing <br />3-8d box (21/2" × 0.113"); or <br />2-8d common (21/2" × 0.131"); or <br />2-10d box (3" × 0.128"); or <br />2 staples, 1" crown, 16 ga., 13/4" long <br />Face nail <br />20 1" × 8" and wider sheathing to each bearing <br />3-8d box (21/2" × 0.113"); or <br />3-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />3 staples, 1" crown, 16 ga., 13/4" long <br />Face nailWider than 1" × 8" <br />4-8d box (21/2" × 0.113"); or <br />3-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />4 staples, 1" crown, 16 ga., 13/4" long <br />Floor <br />21 Joist to sill, top plate or girder <br />4-8d box (21/2" × 0.113"); or <br />3-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />Toe nail <br />22 Rim joist, band joist or blocking to sill or top <br />plate (roof applications also) <br />8d box (21/2" × 0.113")4" o.c. toe nail <br />8d common (21/2" × 0.131"); or <br />10d box (3" × 0.128"); or <br />3" × 0.131" nails <br />6" o.c. toe nail <br />23 1" × 6" subfloor or less to each joist <br />3-8d box (21/2" × 0.113"); or <br />2-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />2 staples, 1" crown, 16 ga., 13/4" long <br />Face nail <br />TABLE R602.3(1)—continued <br />FASTENING SCHEDULE <br />a. Nails are smooth-common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall have minimum <br />average bending yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank diameters larger than 0.142 inch but <br />not larger than 0.177 inch, and 100 ksi for shank diameters of 0.142 inch or less. <br />b. Staples are 16 gage wire and have a minimum <br />7/16-inch on diameter crown width. <br />c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. <br />d. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. <br />e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). <br />f. For wood structural panel roof sheathing attached to gable end roof framing and to intermediate supports within 48 inches of roof edges and ridges, nails shall <br />be spaced at 6 inches on center where the ultimate design wind speed is less than 130 mph and shall be spaced 4 inches on center where the ultimate design <br />wind speed is 130 mph or greater but less than 140 mph. <br />g. Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM C208. <br />h. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor perimeters only. <br />Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor <br />sheathing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall be <br />supported by framing members or solid blocking. <br />i. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter and toe nails from <br />the ceiling joist to top plate in accordance with this schedule. The toe nail on the opposite side of the rafter shall not be required. <br />j. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. <br />TABLE R602.3(1) <br />FASTENING SCHEDULE <br />(continued) <br />ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE <br />OF FASTENERa, b, c SPACING AND LOCATION <br />Roof <br />1 Blocking between ceiling joists or rafters to top plate <br />4-8d box (21/2" × 0.113") or <br />3-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />Toe nail <br />2 Ceiling joists to top plate <br />4-8d box (21/2" × 0.113"); or <br />3-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />Per joist, toe nail <br />3 Ceiling joist not attached to parallel rafter, laps over <br />partitions (see Section R802.5.2 and Table R802.5.2) <br />4-10d box (3" × 0.128"); or <br />3-16d common (31/2" × 0.162"); or <br />4-3" × 0.131" nails <br />Face nail <br />4 Ceiling joist attached to parallel rafter (heel joint) <br />(see Section R802.5.2 and Table R802.5.2)Table R802.5.2 Face nail <br />5 Collar tie to rafter, face nail or 11/4" × 20 ga. ridge strap to <br />rafter <br />4-10d box (3" × 0.128"); or <br />3-10d common (3" × 0.148"); or <br />4-3" × 0.131" nails <br />Face nail each rafter <br />6 Rafter or roof truss to plate <br />3-16d box nails (31/2" × 0.135"); or <br />3-10d common nails (3" × 0.148"); or <br />4-10d box (3" × 0.128"); or <br />4-3" × 0.131" nails <br />2 toe nails on one side and 1 toe nail <br />on opposite side of each rafter or <br />trussi <br />7 Roof rafters to ridge, valley or hip rafters or roof rafter <br />to minimum 2" ridge beam <br />4-16d (31/2" × 0.135"); or <br />3-10d common (3" × 0.148"); or <br />4-10d box (3" × 0.128"); or <br />4-3" × 0.131" nails <br />Toe nail <br />3-16d box 31/2" × 0.135"); or <br />2-16d common (31/2" × 0.162"); or <br />3-10d box (3" × 0.128"); or <br />3-3" × 0.131" nails <br />End nail <br />Wall <br />8 Stud to stud (not at braced wall panels) <br />16d common (31/2" × 0.162")24" o.c. face nail <br />10d box (3" × 0.128"); or <br />3" × 0.131" nails 16" o.c. face nail <br />9 Stud to stud and abutting studs at intersecting wall corners <br />(at braced wall panels) <br />16d box (31/2" × 0.135"); or <br />3" × 0.131" nails 12" o.c. face nail <br />16d common (31/2" × 0.162")16" o.c. face nail <br />10 Built-up header (2" to 2" header with 1/2" spacer)16d common (31/2" × 0.162")16" o.c. each edge face nail <br />16d box (31/2" × 0.135")12" o.c. each edge face nail <br />11 Continuous header to stud <br />5-8d box (21/2" × 0.113"); or <br />4-8d common (21/2" × 0.131"); or <br />4-10d box (3" × 0.128") <br />Toe nail <br />12 Top plate to top plate <br />16d common (31/2" × 0.162")16" o.c. face nail <br />10d box (3" × 0.128"); or <br />3" × 0.131" nails 12" o.c. face nail <br />13 Double top plate splice <br />8-16d common (31/2" × 0.162"); or <br />12-16d box (31/2" × 0.135"); or <br />12-10d box (3" × 0.128"); or <br />12-3" × 0.131" nails <br />Face nail on each side of end joint <br />(minimum 24" lap splice length each <br />side of end joint) <br />Building Code Used For Design: <br />Minnesota Residential Code, 2020 Edition. (IRC 2018) <br />General Notes: <br />1. The intent of these drawings is primarily to provide structural information that <br />may be outside the scope of conventional residential construction. Additional <br />structural information may be found in architectural drawings and should be <br />followed. If any discrepancies are noted, they should be brought to the architect’s <br />and engineer’s attention prior to construction. In addition to these drawings, all <br />structural provisions of the Minnesota Residential Code shall be followed. <br />2. The drawings represent the finished structure. All means and methods not <br />explicitly addressed are the responsibility of the contractor. <br />3. Refer to architectural drawings for dimensions. <br />4. The contractor shall verify/field check, all sizes, dimensions, elevations, locations, <br />etc. of elements which are relative to new construction. <br />5. The contractor shall properly brace the structure during construction. <br />Load Criteria <br />1. Wind Load: <br />Basic Wind Speed, Vult = 115 mph (3 second gust) <br />Building Exposure “C” <br />2. Snow Load: <br />Ground Snow Load, pg = 50 psf <br />Roof Snow Load, pf = 0.7 x pg = 35 psf <br />3. Floor Live Load = 40 psf <br />Footings: <br />1. All footings shall bear on natural undisturbed soil or on compacted granular fill. <br />All footings have been designed for a maximum soil bearing pressure of 2,000 <br />PSF (see geotech report # B2306477 by Braun Intertec). <br />2. Exterior footings shall have a minimum soil cover of 3’-6”. Unheated exterior <br />footings are recommended to have a minimum soil cover of 5’-0”. Soil cover is <br />measured from the bottom of the footing to top of grade. Footing steps shall be <br />located and installed in accordance with the plans. <br />Concrete: <br />1. Concrete work shall conform to all requirements of ACI 301. All concrete <br />shall be normal weight. The minimum compressive strength of concrete shall <br />be as follows: <br />a. Footings - f’c = 5,000 psi. <br />b. Basement walls, foundation walls, garage slabs, exterior walls, garage <br />floor slabs, and exterior slabs – f’c = 4,000 psi (air-entrained, with total <br />air content 5% - 7% by volume) <br /> <br />2. The maximum spacing for contraction joints for a slab-on-grades shall be 36T, <br />where “T” equals the slab thickness. No contraction joint shall exceed 15’-0” for <br />any slab thickness. <br />3. Steel reinforcement shall meet the requirements of ASTM A615, (Fy = 60 ksi). <br />Reinforcement lap splices shall be 60 bar diameters, unless noted otherwise. <br />Structural Wood: <br />1. Dimensional lumber shall be Northern SPF No. 2 or better, UNO. See IRC Table <br />R602.3(1) for fastening schedule. <br />2. All wood in direct contact with concrete, earth, or weathering shall be treated. <br />3. All steel in contact with treated wood (connectors, joist hangers, nails, bolts, etc.) <br />shall be stainless steel or galvanized. <br />4. Engineered lumber shall have the following minimum properties: <br />A. Laminated Veneer Lumber (LVL): <br />Allowable bending stress, Fb = 2,600 PSI (beams) <br />Allowable shear stress, Fv = 285 PSI (beams) <br />Modulus of elasticity, E = 1,900,000 PSI (beams) <br />B. Parallel Strand Lumber (PSL): <br />Allowable bending stress, Fb = 2,400 PSI (columns) <br />Modulus of elasticity, E = 1,800,000 PSI (columns) <br />Compression parallel to grain, Fc|| = 2,500 PSI (columns) <br />C. Laminated Strand Lumber (LSL): <br />Allowable bending stress, Fb = 1,700 PSI <br />Allowable shear stress, Fv = 400 PSI <br />Modulus of elasticity, E = 1,300,000 PSI <br />Compression parallel to grain, Fc|| = 1,400 PSI <br />D. Multi-ply members shall be fastened together according to <br />manufacturer’s recommendations, unless noted otherwise on plans. <br />5. Simpson products called out herein may be replaced with USP or similar of equal <br />or greater capacity. <br />6. Trusses shall be designed to meet all loading and spans as indicated on the plans. <br />All floor trusses shall be designed for a live load deflection of L/480. Truss <br />supplier shall adjust truss spacing as required to meet this requirement. Scissor <br />trusses shall be designed such that horizontal live load deflections do not exceed <br />¾”. <br />Fasteners, Welds & Anchors <br />1. Fasteners and connectors used with treated wood shall be galvanized or coated <br />and qualified to be used with treated wood. <br />2. Bolts used in wood member construction shall have a minimum bolt bending <br />yield strength of Fyb = 45 ksi <br />3. All post-installed anchors shall be as noted on drawings and shall be installed in <br />accordance with the manufacturer’s printed installation instructions and ICC <br />evaluation reports corresponding to that anchor.