My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2785 Shadywood Road - Building Plans: Residential (26)
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2785 Shadywood Road - 21-117-23-24-0054
>
Permits/Inspections
>
2785 Shadywood Road - Building Plans: Residential (26)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 11:35:03 AM
Creation date
11/17/2025 3:10:52 PM
Metadata
Fields
Template:
Address
Street Name
Shadywood Road
House Number
2785
Address
2785 Shadywood Road
PIN
21-117-23-24-0054
Address Doc Type
Building Plans: Residential
Section
Permits/Inspections
Retention Effective Date
11/17/2025
Retention
1 Year After Project Complete Date
Protection
Non-Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />12 <br />3573 3573 3573 <br />3573 3573 3573 2'-0"CHIMNEY SHROUD BY FIRESIDE <br />4'-4"3'-6"4'-4"3'-6"STANDING SEAM METAL ROOF <br />EZE-BREEZE SCREENS <br />OPTION: PHANTOM SCREENS <br />16 <br />12 <br />16 <br />12 <br />3'-0" <br />4 <br />12 <br />TYPICAL ROOF: <br />ROOF VENTS AS REQ'D <br />ARCHITECTURAL ASPHALT SHINGLES <br />ASPHALT FELT PAPER <br />2 COURSES ICE & WATER SHIELD @ ALL EAVES AND <br />VALLEYS AND 100% COVERAGE ON LOWER 6 FT <br />5/8" CDX ROOF SHEATHING <br />ENGINEERED ROOF TRUSSES BY MFR <br />R-49 (MIN) INSULATION: <br />R-35 13" FIBERGLASS BLOWN-IN INSULATION ON <br />R-14 2" CLOSED-CELL SPRAY FOAM INSULATION <br />6 MIL POLY VAPOR BARRIER <br />TYPICAL EXTERIOR WALL: <br />SIDING PER ELEVATION <br />HOUSEWRAP <br />1/2" EXTERIOR PLYWOOD SHEATHING <br />2X6 WOOD STUDS @ 16" O.C. <br />R-20 (MIN) BATT INSULATION <br />6 MIL POLY VAPOR BARRIER <br />1/2" INTERIOR GYPSUM BOARD, SMOOTH FINISH. <br />ALL FENESTRATION: U-FACTOR 0.32 (MAX) <br />4 <br />12 <br />8 <br />12 <br />8 <br />12 <br />TOP OF MAIN LEVEL TOP PLATE <br />TOP OF FDN & TOP OF SLAB AT HOUSE 10'-1 1/8"TOP OF GRADE <br />10" (6" MIN.)1'-6 3/4"TOP OF UPPER LEVEL SUBFLOOR <br />(18" FLOOR TRUSSES) <br />TOP OF UPPER LEVEL TOP PLATE <br />8'-1 1/8"TOP OF FOOTING 4'-0" MIN.-SEE STRUCTTOP OF SLAB AT GARAGE 4"TOP OF GARAGE TOP PLATE <br />9'-7 1/8"6"METAL BRACKET <br />1'-0" <br />1 1/2" <br />4'-0" <br />1'-0" <br />1'-0" <br />1'-0" <br />CORBEL <br />CORBEL <br />8'-7"4'-4"4'-6"16 <br />12 <br />16 <br />12 <br />12 <br />12 <br />13'-6" <br />16 <br />12 <br />TYPICAL ROOF: <br />ROOF VENTS AS REQ'D <br />ARCHITECTURAL ASPHALT SHINGLES <br />ASPHALT FELT PAPER <br />2 COURSES ICE & WATER SHIELD @ ALL EAVES AND <br />VALLEYS AND 100% COVERAGE ON LOWER 6 FT <br />5/8" CDX ROOF SHEATHING <br />ENGINEERED ROOF TRUSSES BY MFR <br />R-49 (MIN) INSULATION: <br />R-35 13" FIBERGLASS BLOWN-IN INSULATION ON <br />R-14 2" CLOSED-CELL SPRAY FOAM INSULATION <br />6 MIL POLY VAPOR BARRIER <br />TYPICAL EXTERIOR WALL: <br />SIDING PER ELEVATION <br />HOUSEWRAP <br />1/2" EXTERIOR PLYWOOD SHEATHING <br />2X6 WOOD STUDS @ 16" O.C. <br />R-20 (MIN) BATT INSULATION <br />6 MIL POLY VAPOR BARRIER <br />1/2" INTERIOR GYPSUM BOARD, SMOOTH FINISH. <br />ALL FENESTRATION: U-FACTOR 0.32 (MAX) <br />TOP OF BONUS ROOM PLATE <br />8 <br />12 <br />1'-0"1'-0" <br />TOP OF MAIN LEVEL TOP PLATE <br />TOP OF FDN & TOP OF SLAB AT HOUSE 10'-1 1/8"TOP OF GRADE <br />10" (6" MIN.)1'-6 3/4"TOP OF UPPER LEVEL SUBFLOOR <br />(18" FLOOR TRUSSES) <br />TOP OF UPPER LEVEL TOP PLATE <br />8'-1 1/8"TOP OF FOOTING 4'-0" MIN.-SEE STRUCTTOP OF SLAB AT GARAGE 4"TOP OF GARAGE TOP PLATE <br />9'-7 1/8"6"METAL BRACKET <br />1'-0"4'-4"4'-6"1 1/2" <br />1'-0" <br />1 1/2" <br />1 1/2" <br />METAL BRACKET <br />CORBEL <br />CORBEL <br />A2.1 <br />EXTERIOR ELEVATIONS <br />ISSUE DATE <br />52.250.141 <br />WINDMILLER DESI*N STUDIO <br />.OS.IE RESIDEN&E2785 SHADYWOOD ROAD ORONO, MN 55331NOTE: <br />WINDMILLER DESIGN STUDIO, LLC. ASSUMES NO <br />RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL <br />ERRORS OR OMISSIONS. WINDMILLER DESIGN STUDIO, <br />LLC. ASSUMES NO RESPONSIBILITY FOR THE <br />WORKMANSHIP OF THE SUB-CONTRACTORS. THE <br />CONTRACTOR AND/OR OWNER MUST VERIFY AND <br />CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS <br />AND FLOOR PLANS AND NOTIFY WINDMILLER DESIGN <br />STUDIO, LLC. OF ANY ERRORS OR OMISSIONS FOR <br />POSSIBLE CORRECTION PRIOR TO THE START OF <br />CONSTRUCTION. <br />© 2024 Windmiller Design Studio. <br />Reproduction solely by Windmiller Design Studio. <br />5.2.24 <br />Exterior Elevation - South <br />1/4" = 1'-0"A2.1 <br />1 <br />Exterior Elevation - East <br />1/4" = 1'-0"A2.1 <br />2
The URL can be used to link to this page
Your browser does not support the video tag.