SECTION 2 - DRAINFIELD SITE CONDITIONS <br />1. STANDARD SYSTEMS. The City will review applications for standard <br />on-site sewage treatment system designs provided each site meets <br />the following minimum conditions necessary for proper functioning <br />of such systems: <br />a. Lot Size: The lot shall have an adequate area for -all. existing <br />and expected improvements in addition to areas of soil suitable <br />for'the installation of two on-site sewage treatment systems, <br />known as the "primary drainfield site" to be used initially, <br />and the "alternate drainfield site" to be used should the primary <br />site ever fail. In all cases,.at least 10,000 square feet of <br />suitable soil and slope shall be identified within each lot' <br />as dedicated for drainfield use. <br />b. Soils: The following soil classification series shall in <br />most.cases be considered suitable for installation of standard <br />systems: <br />Anoka - AnB, AnC Hayden - HbB, HcC2 <br />Braham - B+B, B+C Lester - LrB, LrC, ,LsC2 <br />• Burnsville-- BuB,.BuC, BxB, BxC <br />c. Percolation Rate': The percolation -rate must be faster than <br />60 minutes per inch and slower than 0.5 minutes per inch. <br />.d. Depth to Groundwater or Seasonally Saturated Horizons: For <br />proper functioning of this system -the minimum depth to groundwater <br />or seasonally saturated condition-s.shall be more than 5 feet. <br />e. Flooding Hazard: There must be no hazard of flooding in.the <br />area where these systems are installed. <br />f. Slope: The land slope in the area proposed for the soil absorption <br />field shall not be greater than 12%. <br />-10- <br />