My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1977-12-09 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
E
>
Eileen Street
>
3630 Eileen Street - 05-117-23-21-0013
>
Septic
>
1977-12-09 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2025 2:20:10 PM
Creation date
10/23/2025 2:16:18 PM
Metadata
Fields
Template:
x Address Old
House Number
3630
Street Name
Eileen
Street Type
Street
Address
3630 Eileen Street
PIN
0511723210013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d30N.d'0IlOOr ROddoo* T/N i� 8c TIddAOlo�id, JNQ <br />Zsds '.Haab .lV*4&" 96 <br />dt Aa4 AIJwsadoIa sa/>s <br />Avow 6d6-*600 <br />March 10, 1978 <br />Mr. Michael P. Gaffron <br />Septic System Inspector <br />City of Orono <br />Box 66 <br />Crystal Bay, Mn. 55323 <br />Re: Septic System Design Review <br />Lot 3, Block 1 Aud. Sub 203 <br />Our File No. 139 <br />Dear Mike, <br />Otto G. Eonestroo, T.E. <br />Robert W. Roune, P.E. <br />de Joseph C. Anrltk, P.E. <br />Bradford A. Lentber;, P.E. <br />Robert D. Prtjaard, P.E. <br />Rickard E. Turner, P.E. <br />James C. Olson, P.E. <br />Lawrence P. Feldslen, P.E. <br />Glenn R. Cook, P.F. <br />Keith A. Gordon, P.E. <br />Thom" E. Noyes, P.E. <br />Richard W. Potter, P.F. <br />Robert G. SchoWells, P.E. <br />Marvin L. Sorvela, P.F. <br />Donald C. Ewpprdt, P.E. <br />Kenneth R. Meister, P.E. <br />Charles A. Erickson <br />Leo M. Pewelsky <br />Harlan M. Olson <br />We have reviewed the proposed on -site sewerage design for the Burnhart Residence <br />at Lot 3, Block 1 of Lot 49, Aud. Sub. #203 submitted by Braun Engineering Testing <br />dated Feb. 6, 1978 and offer the following comments. <br />The drainfield as laid out by Braun Engineering is adequate to meet the code re- <br />quirements for a primary drainfield site. Three of the percolation tests are at <br />60 mpi (P-18, P-27 and P-28) and one test is at 54 mpi (P-29). There are 5 dis- <br />tribution lines shown each 80 feet in length yielding 1,000 sq.ft. of trench area <br />which is adequate for a three bedroom home. Two future distribution lines are <br />indicated which would yield a trench area of 400 sq.ft. <br />The two future lines indicated on the drawing are not adequate to meet the require- <br />ments of a secondary drainfield site. The remaining percolation tests around the <br />proposed primary site does not indicate adequate soil for expansion. Therefore, we <br />recommend that it be suggested to the Owner to change the design layout somewhat <br />in order to reserve more room for the secondary site area. For example, if the dis- <br />tribution pipes were changed to 4 lines each 100 feet long, there would be addition- <br />al room for expansion to the sides of the drainfield area. In addition, in pro- <br />posed WPC 40, Section H, 5 (page 720) there are recommended reductions in trench <br />area that can be applied as the result of increasing the depth of filter material <br />below the distribution pipes. <br />In conclusion, it is our opinion that the design as submitted meets the require- <br />ments of a primary site, but we recommend that changes or rearrangements in the <br />design be made in order to reserve adequate space for a secondary site in the same <br />general area as the primary site. <br />Yours very Truly, <br />I�pNESTRbO, ROSENB�?ERLIK 6 ASSOCIATES, INC. <br />Jame�Ols n <br />JCO:li / <br />l <br />
The URL can be used to link to this page
Your browser does not support the video tag.