On tbr• Norris Short' of
<br />Lake ,"innetonka
<br />ON -SITE SEWAGE MEATMENT
<br />INSPECTION REPORT POST OFFICE BOX 66
<br />1335 S. Brown Rd.
<br />Crystal Bay, MN 55323
<br />473-7357
<br />ADDRESS
<br />PERMIT NO.'& - — DATES � ��r�� CONTRACTORS 4-W �',nL�l' P/I
<br />City Ordinance No. 210 requires Ttst a.,ch on -site sewage treatment system in Orono he inspected on a regular basis. The on -site seimi1g'e tJJ
<br />treatment system at the ahntvr address has .men inspected and ep leers to fall into the category checked [slow.
<br />(This is CY an existing system [J new construction)
<br />M1 Meets or exceeds current City standards in all respects relating to design, construction, and lo,:vtinn, Appears Tobe operating
<br />kkproperly.
<br />2 mars rot meat oil current Ci;, _rr,ndards for new construction (1978 Code) but in most respects appears to be designed,
<br />lo-ated, and constructed generally in accordance with previous codes. System appears to be functioning properly: no major
<br />upgrading of tie system is required at this time.
<br />LL:: D 3 Does not n.eet current City standards in many respects relating to design, construction, or 'oeation. Appears to be operating
<br />adequately it this time, but t,as a relatively high pote.rtial for 'uture problems. No major upgrading of system rr squired at
<br />thi- ume.
<br />f-1 4 System n,ay o' ram- of meet current Gity stande -s for design, construction or location, IT, t is fading to properly treat and
<br />�J dislN ;e of tf,e purr. nt input, and is endangering a watst supply, or is a source of pollution to eurfaee of groundwaters, or is
<br />creating a safety narard, or is otherw-se creating a public nuisance. Fiease contact •he Civ, Inspector to diK iss system repair/
<br />replacement pro *dures. If drarnfiald .eplacemen, is necessary, sod tes.ing will usually be required, and a design and site plan
<br />must be submitted for review. lour cun!racloi must obtain a permit before work is its fid
<br />SYSTEM CONDITION ( to Checked items may ter uire your action)
<br />Tank insp-cli , tr.dicotes. ) Inspection pipe is locat-d directly over ta..k baffle. J00" not
<br />❑ Pump(,. -,t needed a this t-me. gi:e accurate measurement of solids accumulation,) If tanks
<br />Pf Solids act,, ^ islion in tanks indicates they should be pump• have not been pumped nut within the lac! t- -e yrors, they
<br />to out this to help prevent future problems. should be pumped cut now.
<br />❑ Solids acA• elation in tanks is at a critical level. Tanks Otainfield inspection indicates_
<br />should be pi.mped out as soon as pu.sible. Drainfield is dry, no surfa.ang evident.
<br />Systr,n is lischarging to surface. Tanks must tsx pumped ❑ Some evidence of surfacing, not critical yet.
<br />within 48 hours to eliminate surface discharge. ❑ Drainfield is sa,nrated and visibly discharging unreated
<br />❑ Inspection risers missing —tanks could not be inspected. effluent to the surface. This condition may require replace
<br />Inspection risers (4" dia, pipe) must be installed in each tank ment or additions to drainheld. Contact the City Inspector
<br />at next purnpout. If tanks have not been pumped out within immediately. Repairs must le completed within 90 days.
<br />tht:.as '`,ree years, they snould be pumped out now. ❑ Drarorield extent and condition unknown.
<br />SITE CHARACTERISTICS
<br />Limiting Site Factors
<br />Potential for System Failure
<br />Site Capabilities for
<br />❑ Slope
<br />idepends on sod tvpes, water
<br />Future Expansion
<br />❑ Sod
<br />table, and ystem condition)
<br />AAdequate
<br />HigF water table
<br />10 Low
<br />❑ Fair
<br />❑ Lot sire
<br />❑ Medium
<br />U Poor
<br />Lake, wetlaou - stream
<br />❑ High
<br />❑ Inadequate
<br />❑ Drainage
<br />❑ System is causing visit •e
<br />surface di -charge.
<br />COMMENTS _
<br />----- ---
<br />---_--- --
<br />Date of Inspection Septic System Inspector
<br />Note In the ev^nt that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised tha!
<br />this report doe- not guarantee or certify that an existing system will continue to function properly, but rs merely an opinion of the adequacy
<br />of The •ystem .order current conditions based on the is odeMe information
<br />This report roust be kept on the premises with syslern location and pumping records
<br />WHITE COPY I Inspector's F:ie GOLD COPY / Homeowner
<br />
|