Laserfiche WebLink
On the Nortb Sbore of <br />ON -SITE SEWAGE TREATMENT Lake .tit innetonka <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1335 S. Bf own Rd. <br />Crystal Say, MN 55323 <br />473-7357 <br />%VNER Nfckr k4e5 NICIIlan ADDRESS � ._��_���•,�+•,,i ��;�IS /Pyr�c� <br />1►FAMIT NO.'S. __535 — DATES i i -12'629 CONTRACTORS <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono he inspected on a regular basis. The on -site se age <br />treatmenr system at the above address has been inspected and appears to fall into the category checked below <br />(This is Tor an existing system ❑ new construction) <br />121 Me-ts or exceeds current City standards in all respects rele!ing to design, construction, and location. Appears to lieoperating <br />} property. <br />2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major <br />upgrading of the system is required at this time. <br />❑ 3 Dcas not meet current City standards in many respects relating to design, construction, or location. Appears to be operat.ng <br />adequatrty at this time, but has a relatively high potential for future, problems. No major upgrading of sysam is required at <br />this time. <br />ED4 System may or Wray, not meet current City ,tandards fur desg 1, car, nruction Of location, but is f;,uhrsg to troperly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />re .ring a safety hazard, (.r ,s otherwise creating a uUic nuisance. Please contact the City Inspector to discuss system repair! <br />replacement procedures. If drainfield replacement is necessary, soil testing wdl usually be required, and a design and site plan <br />must be submitted for revjw. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION 1 10 Checked items may require you, action) <br />Tank inspection indicates <br />,a Pumpout not needed at this time. <br />U Solids accumulation in tanks indicates they should be pump. <br />.d out this year to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risers m,wrig—tanks could not be inspected. <br />Inspection risers 14" die. pipe) must be installed in each tank <br />at next pumpout. If tanks hwve not been pumped out within <br />the last three years, they ss„suld he pumped out now. <br />❑ inspection pipe's located directly over tank baftls,, (Goes not <br />give accurate measurement of solids accumwation.) If tanks <br />have not been pumped out with;n the last three yaws, they <br />should be pumped out now. <br />Grainfield inspection indicates: <br />IR Drainfield is dry, no surfacing a violent. <br />❑ Some eWdence of surfacing, not critical yet. <br />❑ Drainfield is sr. -rated and visibly discherging untreated <br />effluent to the surface. This condition may require teplace- <br />nrent or additions to dranfield. Contact the C,tv Inspector <br />immediatMy. Repairs must be completed within 90 days, <br />J Drsinfield extent and condition unknown. <br />$ITE CHARACTERISTICS <br />Limiting Site Factors <br />❑ Slope <br />Potential for System Failure <br />Site Capabilities for <br />❑ Soil <br />(depends on soil t vps• water <br />Fu[e Expartsion <br />yf <br />❑ HtO water table <br />table. and system con, itionl <br />e�i Low <br />Adequate <br />❑ Fair <br />❑ Lot sire <br />QiMadi _m <br />n Poor <br />❑ Lake, wetland, or stream <br />❑ High <br />Inadegs:ate <br />IJ Drainage <br />❑ System is causing visible <br />surface discharge <br />COMMLrvTS <br />-------------------------- <br />Onto of Inspection Septic Sy I roe <br />Note In the event that this inspection report is -reed to satisfy the require rents for a mortgage or other transfer of property, he advnad that <br />this report does not guarantee or certify that an existing system will continue to function woperly but is merely an opinion o* the adequacy <br />Of the system under current conditions based on the sivur'able information <br />1 his report in use be : on the premises with ivslem location and pumping record!. <br />WHITE COPY / In,uector's File GOLD COPY! Homeowner <br />