Laserfiche WebLink
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />OWNER-- M C Onw�------ — <br />PHONE _ PERMIT NO'S <br />On the North Shore of <br />Lake Alinnetonk:r <br />CIT POST OFFICE BOX 66 <br />OF 1335 S. Brown Rd. <br />O . ONO Crystal Bay, MN 55323 <br />473.7357 <br />ADDRESS 4A-SL_1Q_&jE SKEET --- <br />DATES __ <br />City Ordinance No. 210 requires that _ach on -site sewage treatment system in Orono be inspected on a regular basis. <br />The on -site sewage treatment sy .-,m at the above address has been inspected and appears to fall into the category --hacked <br />below: <br />❑ Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears <br />to be operating properly. <br />❑ Does not meet current city standards in some respects relating to design, construction, or location. Appears <br />to b. operating properly. <br />© Does not meet current city standards in many respects relating to design, construction, or location. Appears <br />to be operating adequately. <br />Does not meet current city standards of design, construction or location, is being overused, or i-. failing to <br />properly treat and dispose of the current input and is therefore endangering a water supply, is a source of <br />pollution to surface or ground%vaters, is creating a safety hazard, or is otherwise creating a public nuisance. <br />Please contact the inspector to discuss requirements for repairs to your system. Soil testing may he ,e- <br />quired. In all cases a design and site plan must be s,rbmitted for rsview. Your contractor must obtain a permit <br />before work is started. <br />WORK REQUIRED: <br />❑ Septi( 'anks must be pumped within 48 hours. <br />Drainfield must be repaired or replaced within 90 days. <br />® Inspection riser (4" diam, pipe) must be installed in each tank. ^T Nr xT /Vm4JiNl� <br />EJTank inspection indicates maintenance pumpout is needed as soon as possible City ordina ice requires that <br />nks be pumped out every three years. <br />SITE CHARACTERISTICS <br />Limitiny Site Factors <br />❑ Slope <br />U sail <br />®High water table <br />® Lot size <br />® Lake, wetland, qLltream <br />❑Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />❑ Low <br />❑ Medium <br />7(�High <br />❑ System s causing visible <br />surface discharge. <br />Site Capabilities for <br />Future Expansion <br />❑ Adequate <br />❑ Fair <br />❑ Poor <br />® Inadequate <br />COMMENTS. TANr A-I&MuLA At P,1MPLza EVi�X_ 3 XCARS 7-0 /'�'�ttue1t Sc�ss05 <br />r-gslyn CN L R Uk. Ant D q.AoralufSlil I3Mi1UC--ic-1 *1 1 itU.4 5 . AAiA 'Z.-A/A/VCC 1.S_ <br />Date of Inspection Sdatic System Inspector <br />This report must be kept on the premises with system location and pumping records. <br />WHITE COPY / inspector's File GOLD COPY / Homeowner <br />