1993-10-11 Letter, Revised Septic Design
Orono
>
Property Files
>
Street Address
>
E
>
East Long Lake Road
>
550 East Long Lake Road - 35-118-23-14-0002
>
Septic
>
1993-10-11 Letter, Revised Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2025 3:13:34 PM
Creation date
10/9/2025 3:06:08 PM
Metadata
Fields
Template:
x Address Old
House Number
550
Street Name
East Long Lake
Street Type
Road
Address
550 East Long Lake Road
PIN
3511823140002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . .` i .. • <br />=P TESTtNG, INC. Steven B. Schirmem — MPCA Cert. No. 627 <br />951 Katydid Lane NE • St. Michael, MN 55376 * (612) 497-35M <br />October 11, 1993 <br />Taylor Residence <br />Bruce Schmidt & Associates <br />550 East Long Lake Rd. <br />Orono, Henn. Co., MN <br />This letter is in reguard with the Revised Design for the proposed <br />On -Site Sewage Treament System for this property. <br />The proposed sites were compacted from equipment travel. The <br />average percolation rates from the tests completed June 28, 1993 <br />was 10.6 min/inch. The tests completed September 25 & 30 range <br />from 7 to 480.0 min/inch. The proposed treatment area is compacted <br />approx. 101 & the future expansion area is compacted approx. 401. <br />when installing the primary site, the compacted area must be <br />turned over 180 deep (only compacted area). The holes from tree <br />removal must be filled with a loam soil, not sand. The future <br />expansion area (3 seperate rock beds 27.3' each) must be turned <br />over at the same time as the installation of the primary site. <br />Recommend to use a chisel plow 180 deep. <br />These sites no longer meet State & l ^al Code due to the <br />compacted soils. This Design must reviewed & approved <br />by the City Official. <br />Note : Septic effluent will to be delivered by a timer, 300ga: /day <br />per mound. Pumping chamber will also need a alternating relay <br />alternating each mound. <br />even B'Achi; e <br />�U <br />SBS/ds <br />