1987-09-04 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
E
>
East Long Lake Road
>
550 East Long Lake Road - 35-118-23-14-0002
>
Septic
>
1987-09-04 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2025 3:13:34 PM
Creation date
10/9/2025 3:05:47 PM
Metadata
Fields
Template:
x Address Old
House Number
550
Street Name
East Long Lake
Street Type
Road
Address
550 East Long Lake Road
PIN
3511823140002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />OWNER Plan k <br />PERMIT NO.'S. <br />DATES <br />On the Nortb ,Shore of' <br />Lake.titin netonkit <br />POST OFFICE BCX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473.7357 <br />ADDRESS 50 &--if Lo (cad take �oad <br />CON RACTORS <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage <br />treatment system at the above address has been inspected and appears to fall into the category thanked below <br />(This is X an existing system ❑ new construction) <br />El' Meets or exceeds current City standards in all respects relating to design, constn.c•mc, and location. Appears to be operating <br />properly. <br />CR2 Does not meet all current City standards for new construction (1978 Code) but in .Host respects npeers to be designed. <br />located, and constructed generally in accordance with previous codes. System appears to lie functioning properly, no major <br />upgrading of the system is required at this time. <br />03 Does not meet current City standards in many respects relating to design, construction, or locatio. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading A system is required at <br />this time. <br />4 System may or may not meet current City standards for design, construction of Location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drairtheld replacement is necessary, soil testing will usually be requited, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION 1 (0 Checked items may require your action) <br />Tank inspection indicates: <br />IJ Pumpour n t needed at this time. <br />tl Solids accumulation in tanks indicates they should be pump- <br />ed out this year to help prevert future problems. <br />E3 Solids sccumulatoon in tanks is at a critical lever. Tanki <br />should be pumped out as soon as possible. <br />n System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risen missing —tanks :ould not be inspected. <br />Inspect.,sn risers 14" die. pipe) must be installed in each tank <br />at next pumpout. If tanks hew not been pumped out within <br />the last three years, they should be pumped out now. <br />SITE CHARACTERISTICS <br />h Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfiefd inspection indicates: <br />❑ Drainfield is dry, no surfacing evident. <br />X Some evidence of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions 'i drainheld. Contact the Cot Inspector <br />irr-*diatefy. Repairs must be completed within 90 days. <br />❑ Dramfield extt�t and condition unknown. <br />Limiting Site Factors Potential for System Failure <br />Site Capabditiet for <br />❑ Slone (depends on sod types, water <br />❑ Soil <br />Future Fxpansion <br />table, and system condition) <br />❑ High water table ❑ <br />X Adequate <br />Low <br />❑ Lot site Dit Medium <br />CJ Fair <br />❑ Poor <br />❑ Lake, wetland, at stream High <br />L 1 Inadequate <br />❑ Drainage ❑ System is ca-isrng visible <br />surface discharge. <br />COMMENTS: <br />Date of Inspection Septic Sy Spector — <br />Note In the event that this insper Lion report is used to satisfy the requirements for a mortgage or other it .:islet of <br />property, be advised t-ia- <br />this report does not guarentee or certify That an existing system will continue to function properly, !,tit is inerely an <br />opinion of the adequacy <br />Of the system under current conditions based on the wadable information <br />This report must be kent on the t rnise• With system location anu p pmb &cords <br />WHITE COPY / Inspector's File GOLD :OP`• r Homeowner <br />