NORTHFOUNDATION PLAN <br />SCALE 1/8" = 1'-0" <br />2B <br />A099 <br />17'-0" <br />C D F <br />FC.9C.3 <br />4 <br />3 <br />2 <br />1 <br />2.7 <br />2.5 <br />20'-0"15'-0"1'-8" <br />11'-0" <br />2.1 <br />2 <br />1 <br />312'-0"10'-0"37'-0"10'-0"12'-0"4'-0"33'-0"13'-912"11'-11"12'-234"14'-734"FROM FACE OF FND WALL4'-8"8'-0"M.O.4'-0"8'-0" <br />M.O. <br />3'-0"3'-4"8'-8" <br />M.O. <br />16'-8"10'-4"4'-0" <br />M.O. <br />4'-8"14'-0"11'-4" <br />WDW WELL 4'-0"1.3 <br />C.5 <br />10'-0" <br />5'-4" <br />B.8 <br />B.8 <br />10'-0" <br />[2] HELICAL SCREW PIERS, FOR LOAD <br />CALCULATION AND MIN BEARING CAPACITY <br />OF PIER AND MOUNTING PLATE, SEE STRUCT <br />B.9 <br />B.9 <br />FULL-DEPTH <br />EXCAVATION <br />8'-0"5'-4" <br />4 <br />E <br />CONC STRIP FOOTING, SEE STRUCT <br />A <br />A <br />COMPLETELY BACKFILL W/ SOIL, COMPACT <br />B <br />B <br />16'-0" <br />7'-0" <br />TO C/L OF PIER <br />5 <br />5 <br />27'-0" <br />47'-8" <br />4 <br />REINFORCED CONC SLAB ON GRADE <br />2X10 PT WD JOISTS, <br />16" O.C., HANGER <br />FOR RIM JOIST AND HELICAL SCREW PIER, SEE <br />STRUCT FOR SIZE, LOAD CALCULATION AND MIN <br />BEARING CAPACITY OF PIER AND MOUNTING PLATE <br />WDW WELL20°CCWFOUNDATION PLAN NOTES <br />GSF CALCULATION BY EXCAVATION TYPE <br />GROSS SQ FT [GSF] = OUTSIDE FACE OF FOUNDATION WALLS <br />FULL-DEPTH EXCAVATION <br />2,429 GSF BASEMENT & STORAGE <br />SLAB-ON-GRADE/STEM WALL <br />1,287 GSF GARAGE <br />GARAGE ROTATION <br />1.GARAGE HAS BEEN ROTATED 20° CCW <br />2.ROTATION SHOWN IN FLOOR PLANS ONLY. ELEVATIONS AND SECTIONS ARE <br />DRAWN ORTHOGONALY FOR EASE OF UNDERSTANDING DRAWING INFORMATION <br />N3N2N1L4L3L2L1 <br />> FOUNDATION, REQUIREMENTS [R401.2] <br />FOUNDATION CONSTRUCTION SHALL BE CAPABLE OF <br />ACCOMMODATING ALL LOADS AND OF TRANSMITTING THE <br />RESULTING LOADS TO THE SUPPORTING SOIL. SOILS THAT SUPPORT <br />FOOTINGS AND FOUNDATIONS SHALL BE DESIGNED, INSTALLED AND <br />TESTED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE. <br />> GEOTECHNICAL EVALUATION [R401.4.1] <br />IN LIEU OF A GEOTECHNICAL EVALUATION, THE FOLLOWING <br />LOAD-BEARING VALUES SHALL BE ASSUMED [R401.4.1]: <br />CRYSTALLINE ROCK 12,000 PSF <br />SEDIMENTARY ROCK 4,000 PSF <br />SANDY GRAVEL, GRAVEL [GROUP I]3,000 PSF <br />SAND, GRAVEL, SILT, CLAY [GROUP II]2,000 PSF <br />CLAY, SILT [GROUP III/IV]1,500 PSF <br />WHERE SOILS WITH A BEARING CAPACITY OF LESS THAN 1,500 PSF <br />ARE LIKELY PRESENT, LOAD BEARING CAPACITY SHALL BE <br />DETERMINED BY A SOILS INVESTIGATION. <br />> CONCRETE, COMPRESSIVE STRENGTH [TABLE R402.2] <br />UNLESS SPECIFIED BY A STRUCTURAL ENGINEER, CONCRETE SHALL <br />HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH IN THE <br />FOLLOWING AREAS: <br />FOOTINGS*5,000 PSI <br />BASEMENT WALLS, FOUNDATIONS, SLABS 2,5OO PSI <br />GARAGE SLABS 3,000 PSI <br />*COMPRESSIVE STRENGTH OF 2,500 PSI, WITH AN APPROVED <br />ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT <br />LEAST EQUIVALENT TO 5,000 PSI CONCRETE. <br />> FOOTINGS, GENERAL [R403.1] <br />ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUS SOLID <br />OR FULLY GROUTED MASONRY OR CONCRETE FOOTINGS, CRUSHED <br />STONE FOOTINGS, WOOD FOUNDATIONS, OR OTHER APPROVED <br />STRUCTURAL SYSTEMS WHICH SHALL BE OF SUFFICIENT DESIGN TO <br />ACCOMMODATE ALL LOADS AND TO TRANSMIT THE RESULTING <br />LOADS TO THE SOIL WITHIN THE LIMITATIONS AS DETERMINED FROM <br />THE CHARACTER OF THE SOIL. FOOTINGS SHALL BE SUPPORTED ON <br />UNDISTURBED NATURAL SOILS OR ENGINEERED FILL. <br />> VENTILATION [408.1] <br />THE UNDER-FLOOR SPACE SHALL HAVE VENTILATION OPENINGS <br />THROUGH FOUNDATION WALLS. THE NET AREA OF VENTILATION <br />OPENINGS SHALL BE 1 SF [MIN] FOR EACH 150 SF OF UNDER-FLOOR <br />SPACE. WHEN CLASS 1 VAPOR RETARDER IS USED, THE MINIMUM <br />NET AREA OF VENTILATION OPENINGS SHALL BE 1 SF [MIN] FOR <br />EACH 1,500 SF OF UNDER-FLOOR SPACE. ONE SUCH VENTILATING <br />OPENING SHALL BE WITHIN 3' OF EACH CORNER OF THE BUILDING. <br />> ACCESS, BELOW-FLOOR [R408.4] <br />ACCESS SHALL BE PROVIDED TO ALL UNDER-FLOOR SPACES. <br />OPENINGS THROUGH A PERIMETER WALL SHALL BE 16"X24" [MIN]. <br />> REMOVAL OF DEBRIS [R408.5] <br />THE UNDER-FLOOR GRADE SHALL BE CLEANED OF ALL VEGETATION, <br />ORGANIC MATERIAL AND CONSTRUCTION MATERIALS BEFORE A <br />BUILDING IS OCCUPIED. <br />FOUNDATION SYSTEM SPECIFICATIONS MINNESOTA RESIDENTIAL CODE, 2015 <br />FOUNDATION & EXTERIOR WALL TYPES SEE FRAMING PLANS [A250-A253] FOR WALL TYPE TAGS <br />POURED REINFORCED CONC <br />[SEE A100 FOR SIZE] <br />CMU <br />12" EXT GRADE PLY WD <br />VAPOR BARRIER <br />RIGID INSUL <br />LIQUID WATERPROOFING <br />CLOSED CELL INSUL <br />CMU <br />[SEE A100 FOR SIZE] <br />CMU <br />LIQUID WATERPROOFING <br />RIGID INSUL, EXT <br />VAPOR BARRIER <br />12" EXT GRADE PLY WD <br />RIGID INSUL, INT <br />CMU <br />12" EXT GRADE PLY WD <br />VAPOR BARRIER <br />RIGID INSUL <br />LIQUID WATERPROOFING <br />RIGID INSUL, INT <br />POURED REINFORCED CONC <br />LIQUID WATERPROOFING <br />DRAINAGE/PROTECTION MAT <br />RIGID INSUL <br />REINFORCED POURED CONC <br />LIQUID WATERPROOFING <br />DRAINAGE/PROTECTION MAT <br />RIGID INSUL [EXT & INT] <br />N4 <br />REINFORCED POURED CONC <br />LIQUID WATERPROOFING <br />DRAINAGE/PROTECTION MAT <br />RIGID INSUL [EXT & INT] <br />8" THICK <br />N4 <br />8" THICK N4 <br />N4 <br />FOR PORCH FLOOR FRAMING SIZING <br />AND ATTACHMENT, SEE STRUCT <br />10" THICK <br />N1 <br />15'-912" STRIP FTNG <br />FROM FACE OF FND WALL <br />8" THICK <br />N2 <br />8" THICK <br />N3 17'-1"STRIP FOOTING8" THICK <br />N2 <br />8" THICK <br />N1 <br />POURED REIN CONC FND WALL, SEE STRUCT2'-0"CONC STRIP FOOTING, <br />SEE STRUCT <br />2'-4" <br />9'-0" <br />SINGLE <br />G <br />A <br />R <br />A <br />G <br />E <br />D <br />R <br />2'-6" <br />16'-0" <br />DOUBLE <br />G <br />A <br />R <br />A <br />G <br />E <br />D <br />R <br />5'-0" <br />3'-2" <br />DR <br />T.O. WALL <br />+3'-4"4'-0"CONC FTNG, <br />SEE STRUCT <br />CONC FTNG, SEE STRUCT <br />CONC STRIP FTNG, SEE STRUCT <br />8" THICK <br />N4 <br />CONC FTNG, SEE STRUCT <br />FOR CONC STRIP FOOTING SIZE, SEE STRUCT <br />REIN CONC PAD FOOTING, <br />SEE STRUCT <br />34'-8" <br />52'-0" <br />59'-0"15'-0"49'-0"63'-0"49'-0"45'-8" <br />9'-1012" <br />T.O. WALL <br />+3'-4"T.O. FTNG0'-0"T.O. FTNG <br />0'-0" <br />T.O. WALL <br />+5'-8" <br />PLASTIC SUMP BASKET AND PUMP, 24" Ø, 2'-6" DEEP <br />8" THICK <br />N3 <br />T.O. FTNG <br />0'-0" <br />T.O. WALL <br />9'-0" <br />T.O. WALL <br />9'-0"T.O. WALL9'-0"T.O. FTNG0'-0"T.O. WALL9'-0"2X10 PT LEDGER <br />BLK'G AT MIDSPAN <br />PERFORATED T-SHAPED RADON <br />PIPE IN ROCK BED, FILTER FABRIC <br />PVC RADON PIPE VENT UP <br />STAIR WALL THRU ROOF CONC STRIP FOOTING, <br />SEE STRUCT <br />4" PERFORATED DRAIN TILE IN ROCK BED WRAPPED FILTER <br />FABRIC, CONNECT INTR W/ EXT DRAIN TILE W/ PVC SLEEVE <br />5'-11" <br />CONC PAD FTNG, SEE STRUCT <br />ROUTE DRAIN TILE TO DAYLIGHT <br />WDW WELL FTNGS SAME <br />DEPTH AS MAIN HOUSE <br />CONC FTNG, SEE STRUCT <br />INTR DRAIN TILE, CONT <br />AT FTNG PERIMETER <br />INTR DRAIN TILE, CONT <br />AT FTNG PERIMETER <br />INTR DRAIN TILE, CONT <br />AT FTNG PERIMETER <br />4'-0"PAD FOOT <br />ING <br />4'-0" <br />PAD FO <br />O <br />TI <br />N <br />G14'-8"STRIP <br /> FOOT <br />ING <br /> LENGTH9'-3"STRIP <br /> FOOT <br />ING <br /> LENGTH4'-0" <br />4'-0"13'-0 <br />" <br />REIN POURED CONC STEM WALL, <br />SEE STRUCT <br />REIN CONC PAD FOOTING, <br />SEE STRUCT 3'-0" <br />2'-4 1 4 " <br />9'-8"1'-7"4'-8"10'-10"15'-9"1'-73 4" <br />4'-8"4'-8"18'-312" <br />CONC PAD <br />FOOTING, <br />SEE STRUCT <br />11'-6"4" PVC SLEEVE THRU FTNG, CONNECT INTR W/ <br />EXTR DRAIN TILE, SEAL PIPE PENETRATION <br />4" PVC SLEEVE THRU FTNG, <br />CONNECT INTR W/ EXTR DRAIN <br />TILE, SEAL PIPE PENETRATION <br />4" PVC SLEEVE THRU FTNG, CONNECT INTR <br />W/ EXTR DRAIN TILE, SEAL PIPE PENETRATION 4'-0"13'-4"210 Bederwood Drive <br />Orono, MN 55356 <br />COMM. NO. <br />DATE <br />DRAWN BY <br />MAN2202 <br />25-APR-24 <br />DVL <br />CHECKED BY DVL <br />PROJECT ADDRESS <br />DRAWING TITLE <br />Manchester Residence <br />New Construction <br />PROJECT <br />REVISONS <br />SHEET NUMBER <br />© 2024 david lund design <br />CONTACT <br />info@davidldesign.com <br />(612) 209-0913 <br />MEASURED BY N/ADESIGN PHASEDRAWING DEVELOPMENT1345678910DESIGN REVIEW STATUS <br />1 2 DONECONSTRUCTION DOCUMENT | 4/42EXST <br />D E S I G N E D I N M I N N E A P O L I S <br />a099 <br />Foundation Plan <br />Reviewed for Code Compliance <br />Nicole Post <br />RPS223-000195 <br />6-12-24 <br />Replaces engineered stamped plans of <br />5/15/24