1982-01-05 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
D
>
Dickey Lake Drive
>
736 Dickey Lake Drive - 27-118-23-33-0006
>
Septic
>
1982-01-05 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2025 12:08:04 PM
Creation date
9/17/2025 12:02:48 PM
Metadata
Fields
Template:
x Address Old
House Number
736
Street Name
Dickey Lake
Street Type
Road
Address
736 Dickey Lake Road
PIN
2711823330006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1615 Ringer Subdivision <br />page 5 <br />Lot 6, Block 1 <br />Peres PB61 thru PB66. Borings BB61 thru BB63. Average perc <br />rates at both sites are acceptable. Slopes range from 2 to 48. <br />Mottling started at a depth of approximately 2.4 feet, with <br />actual water level at 2.5 to 4.41. A standard mound system <br />should be used at both sites. <br />Lot 7, Block 1 <br />Peres PB71 thru PB76. Borings BB71 thru BB73. Slopes average 2-3%. <br />Perc rates were fairly slow, with the secondary si.ce being somewhat <br />slower than the limit (however, the justification for Lot 5, <br />Block 1 also applies here). Actual water level ranged from 1.7 <br />to 3.5' with mottling generally below 2.5'. A standard mound is <br />recommended for both sites. <br />Lot 1, Block 2 <br />Peres PA11 thru PA18. Borings BAll thru BA13. Slopes are very <br />flat. Mottling was indicated below 2.2 ' with actual water <br />encountered below 2.01. Two secondary sites were tested. All <br />sites are acceptable for a standard mound system. <br />Lot 2, Block 2 <br />Peres PA21 thru PA26. Borings BA21 thru BA23. very flat slopes. <br />Mottling occurs at 2.0 to 2.4' with actual water encountered <br />below 2.41. Perc rates on both sites are acceptable. A mound <br />system is recommended for both sites. <br />Lot 31 Block 2 <br />Peres PA31 thru PA36. Borings BA31 thru BA33. Slopes averaged <br />2 to 51. Mottling starts at a depth of 2.0-3.51. Actual water <br />level was below 2.5'. Perc rates are acceptable. Mound systems <br />are recommended for both sites. <br />Lot 4, Block 2 <br />Peres PA41 thru PA46. Borings BA41 thru BA43. Slopes are very <br />flat. Mottling generally was found below 2.01, with actual <br />water level at abu ut 4.01. Perc rate for primary site is <br />acceptable; perc rate for secondary site iL slightly slow but <br />acceptable for a mound based on the justification referred to <br />for Lot 5 Block 1. I recommend a mound system for both sites. <br />Lot 5, Block 2 <br />Peres PA51 thru PA56. Borings BA51 thru BA53. Slopes are very <br />flat. Mottling occurred below 1.2 feet with actual water below <br />4.0 feet. Perc rates are acceptable for the primary site and <br />slightly slow at the secondary site. (Refer to Lot 5, Block 1) <br />This lot has the overall worst set of percolation rates of the <br />division. 'However, only two of the peres were taken in the <br />topsoil, the others, two of which were very slow, 4ere at depth. <br />I recommend that a mound system be used on this site. If peres <br />were re -taken in the topsoil, it is likely they would pass as <br />did nearly all others done in this manner. <br />