Laserfiche WebLink
3- 1 3/4" x 9 1 /4" LVL BEAM, FLUSH, <br />HUC610 HANGER MAX w/ #10 x 2 112 <br />/ <br />SD SCREWS @ INT. F.O. BEAM <br />1 \�_ <br />_ _ _ 6 x 6 TREATED POST, <br />08 <br />LCE4Z CAP EACH FACE, <br />I <br />MSTA1 8Z VERT. STRAP, ABU66Z BASE <br />= l <br />w/ 5/8" x 6" SIMPSON TITEN, <br />1 2" � x 60" CONC. PIER w/ 1 - #4 VERT. <br />L.L l <br />REBAR, 24" N BOT. BELL w/ COMPACTED <br />X <br />I <br />GRANULAR BACKFILL AND COMPACTED <br />Q <br />l <br />BASE OF EXCAVATION <br />co <br />j <br />I <br />2 x 10 FLOOR JOISTS @ 1 6" o.c. <br />m J! <br />w/ LUS210 HANGERS E.E. <br />l 2 x 10 LEDGER w/ 2- ROWS 1 /4" x 3 1 /2" <br />SDS SCREWS @ 1 6" o.c. TO EXISTING 2 x 10 RIM <br />I <br />I <br />I <br />EXISTING FLOOR JOISTS ASSUMED, <br />FIELD VERIFY AS REQ. <br />------------- <br />I <br />I <br />J <br />---_1 _ ___ <br />0 <br />GENERAL NOTES: <br />01. FIELD VERIFY EXISTING DIMENSIONS RELEVANT TO REMODEL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT WITH ANY DISCREPANCIES <br />AND/OR QUESTIONS PRIOR TO CONSTRUCTION. <br />02. FIELD VERIFY ALL EXISTING ELECTRICAL, MECHANICAL, AND/OR PLUMBING CONDITIONS RELEVANT TO REMODEL PRIOR TO CONSTRUCTION. <br />03. DO NOT SCALE DIMENSIONS OFF OF DRAWINGS FOR CONSTRUCTION. CONTACT ARCHITECT WITH ANY QUESTIONS ON DIMENSIONS PRIOR <br />TO CONSTRUCTION. <br />04. FIELD VERIFY ALL EXISTING LOAD BEARING CONDITIONS PRIOR TO DEMOLITION. BRACE AND SUPPORT ALL EXISTING CONDITIONS TO <br />REMAIN AS REQUIRED DURING DEMOLITION AND THROUGHOUT CONSTRUCTION. <br />2 x 10 LEDGER w/ 3 - ROWS 1 /4" x 3 1 /2" SDS SCREWS @ 1 6" o.c. TO EXISTING 2 x 10 RIM, <br />REMOVE BUILT -RITE SHEATHING IF EXISTS AND REPLACE w/ 3/4" PLY. GLUED + NAILED TO FRAMING <br />POCKET BEAMS INTO WALL, BEAR 3" ONTO WALL PLATE <br />ONTO 2 - 2 x 6 STUDS, ATTACH TO PLATE w/ 4 - 1 /4" x 3 1 /2" SDS TOE -SCREWS, <br />ATTACH TO RIM w/ LSTA1 2 HORIZ. STRAP AND LSTA18 VERT. STRAP TO POST <br />PLAN - main level framing addition + remodel <br />SCALE:1/4" = V-0" <br />Wallace <br />ARCHITECTURE, PLLC <br />311 Third Street <br />Excelsior, MN 55331 <br />952.913.9641I <br />These documents are instruments of <br />service, and, as such, remain the <br />property of wallace ARCHITECTURE, <br />pllc. Use or publication of these <br />documents requires written approval <br />from wallace ARCHITECTURE, pllc. <br />Q0 <br />Q <br />O <br />+ <br />_0 <br />O <br />O <br />L0 <br />M <br />� <br />Ur <br />_O <br />}' <br />. <br />Z <br />� <br />J <br />+-+ <br />p <br />C9 <br />O <br />J <br />Project Number: <br />2410 <br />Project Architect: <br />Dan Wallace <br />Drawn By: <br />Dan Wallace <br />Date of Issue: <br />BID.1 - 25 Jan 2025 <br />21 Jan 2025 <br />DD.1 - 18 Dec 2024 <br />SD.1 - 12 Dec 2024 <br />04 <br />69 <br />